grade
certified reference material
manufacturer/tradename
Hellma 667-UV305
application(s)
food and beverages
petroleum
pharmaceutical
plastics
format
neat
正在寻找类似产品? 访问 产品对比指南
General description
Consisting of :
60 mg Potassium dichromate in perchloric acid (667-UV60, wavelength 235; 257; 313; 350 nm)
600 mg Potassium dichromate in perchloric acid (667-UV600, wavelength 430 nm)
Perchloric acid reference filter (667-UV14, wavelength 235; 257; 313; 350 nm)
Potassium dichromate dissolved in perchloric acid is a highly suitable method to check for photometric accuracy (absorbance) in the UV region. Potassium dichromate gives a spectral scan containing characteristic peak maxima at 257 nm and 350 nm and minima at 235 nm and 313 nm. The potassium dichromate solution is sealed in an airtight sealed quartz precision cell with 10 mm light path. The absorbance values of the filter are determined at the wavelengths 235 nm, 257 nm, 313 nm, and 350 nm and are specified in the certificate. It should be noted that the measurements are carried out with the filter 667-UV14 (0.01 N perchloric acid) in the reference beam path. Measured values of the reference filter are separately displayed in the certificate.
60 mg Potassium dichromate in perchloric acid (667-UV60, wavelength 235; 257; 313; 350 nm)
600 mg Potassium dichromate in perchloric acid (667-UV600, wavelength 430 nm)
Perchloric acid reference filter (667-UV14, wavelength 235; 257; 313; 350 nm)
Potassium dichromate dissolved in perchloric acid is a highly suitable method to check for photometric accuracy (absorbance) in the UV region. Potassium dichromate gives a spectral scan containing characteristic peak maxima at 257 nm and 350 nm and minima at 235 nm and 313 nm. The potassium dichromate solution is sealed in an airtight sealed quartz precision cell with 10 mm light path. The absorbance values of the filter are determined at the wavelengths 235 nm, 257 nm, 313 nm, and 350 nm and are specified in the certificate. It should be noted that the measurements are carried out with the filter 667-UV14 (0.01 N perchloric acid) in the reference beam path. Measured values of the reference filter are separately displayed in the certificate.
Application
Hellma® liquid calibration standards set for checking the photometric accuracy of spectrophotometers in accordance with European Pharmacopoeia (Ph. Eur.) and U.S. Pharmacopeia (USP) 857.
Features and Benefits
- Accredited to DAkkS Deutsche Akkreditierungsstelle (National accreditation body for the Federal Republic of Germany)
- Traceable to NIST (National Institute of Standards and Technology)
- Assured Quality of the measurement results
- Proven accuracy and reliability
Legal Information
Hellma is a registered trademark of Hellma GmbH
存储类别
10 - Combustible liquids
flash_point_f
Not applicable
flash_point_c
Not applicable
wgk
WGK 3
法规信息
危险化学品
此项目有
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.