refractive index
n20/D 1.386 (lit.)
bp
99 °C (lit.)
density
0.872 g/mL at 25 °C (lit.)
storage temp.
2-8°C
SMILES string
CC(C)CCON=O
InChI
1S/C5H11NO2/c1-5(2)3-4-8-6-7/h5H,3-4H2,1-2H3
InChI key
OWFXIOWLTKNBAP-UHFFFAOYSA-N
正在寻找类似产品? 访问 产品对比指南
Other Notes
This product has been replaced by 150495-Sigma-Aldrich | Isopentyl nitrite 96%
signalword
Danger
Hazard Classifications
Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Dam. 1 - Flam. Liq. 2 - Muta. 2 - Skin Corr. 1B - Skin Sens. 1
存储类别
3 - Flammable liquids
wgk
WGK 3
flash_point_f
-4.0 °F - closed cup
flash_point_c
-20 °C - closed cup
ppe
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
法规信息
新产品
此项目有
D C Rees et al.
Neurobehavioral toxicology and teratology, 8(2), 139-142 (1986-03-01)
Mice were examined for effects on lethality and motor performance on an inverted screen test following inhalation exposure to isoamyl, n-butyl and isobutyl nitrite. All three nitrites produced concentration-related effects on both measures, with EC50s for motor performance only about
R M Uppu et al.
Analytical biochemistry, 236(2), 242-249 (1996-05-01)
A new method for the preparation of high concentrations of peroxynitrite (up to 1 M) is described. The synthesis uses a two-phase system and involves a displacement reaction by the hydroperoxide anion (in the aqueous phase) on isoamyl nitrite (in
Hossein Mehrabi
Ultrasonics sonochemistry, 15(4), 279-282 (2007-10-26)
The reaction of 6-acylmethylphenanthridines with isoamyl nitrite results alpha-oximino-6-acylmethylphenanthridines in 73-95% yields in DMF under ultrasound irradiation. Compared with conventional methods, the main advantages of the present procedure are milder conditions, shorter reaction time and higher yields.
The cycloaddition reaction of I(h)-Sc₃N@C₈₀ with 2-amino-4,5-diisopropoxybenzoic acid and isoamyl nitrite to produce an open-cage metallofullerene.
Guan-Wu Wang et al.
Angewandte Chemie (International ed. in English), 50(20), 4658-4662 (2011-04-16)
A Ahsan et al.
Clinical and applied thrombosis/hemostasis : official journal of the International Academy of Clinical and Applied Thrombosis/Hemostasis, 6(3), 169-174 (2000-07-18)
Because the subcutaneous absorption of heparin depends on its molecular weight, high performance size exclusion chromatography methods, among others, have been developed for its determination. Because heparin consists of polymer chains of varying lengths, a large number of calibrators, 19
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系客户支持