登录 查看组织和合同定价。
选择尺寸
关于此项目
经验公式(希尔记法):
C32H55NO25
化学文摘社编号:
分子量:
853.77
UNSPSC Code:
12352200
MDL number:
Beilstein/REAXYS Number:
6050703
SMILES string
C[C@@H]1O[C@@H](O[C@H]2[C@H](O)[C@@H](NC(C)=O)[C@@H](O[C@@H]2CO)O[C@H]3[C@@H](O)[C@@H](CO)O[C@@H](O[C@@H]4[C@@H](CO)OC(O)[C@H](O)[C@H]4O[C@@H]5O[C@H](CO)[C@H](O)[C@H](O)[C@H]5O)[C@@H]3O)[C@@H](O)[C@H](O)[C@@H]1O
biological source
human milk
assay
≥98% (HPAE/PAD)
storage temp.
2-8°C
正在寻找类似产品? 访问 产品对比指南
存储类别
13 - Non Combustible Solids
wgk
WGK 3
flash_point_f
Not applicable
flash_point_c
Not applicable
ppe
Eyeshields, Gloves, type N95 (US)
法规信息
新产品
此项目有
Alexander Pirkl et al.
Analytical chemistry, 84(13), 5669-5676 (2012-06-08)
Although water ice has been utilized in the past as a matrix for infrared matrix-assisted laser desorption/ionization mass spectrometry (IR-MALDI-MS), it has not found a wider use due to limitations in the analytical performance and technical demands on the employment
Q Xu et al.
Glycobiology, 6(3), 281-288 (1996-04-01)
Three-bond heteronuclear coupling constants (3JCH) are extremely useful in describing flexible models for oligosaccharides. We show that antiphase methods for measuring 3JCH in oligosaccharides have limited reliability but that the coupling constants can be reliably measured in natural abundance by
H Kogelberg et al.
Biochemistry, 35(6), 1954-1964 (1996-02-13)
This investigation is focused on the conformational behavior of the blood group Lewisa (Le(a)-active pentasaccharide lacto-N-fucopentaose II (LNFPII) and its sulfated and sialylated analogs, SuLNFPII and SLNFPII. The latter two are more potent oligosaccharide ligands for the animal lectins, E-
Jens Soltwisch et al.
Analytical chemistry, 81(8), 2921-2934 (2009-03-24)
Matrix-assisted laser desorption ionization (MALDI) allows for the mass spectrometric (MS) analysis of thermally labile, non-volatile biomolecules. However, some residual analyte fragmentation typically accompanies the phase transition from the condensed to the gas phase and following plume expansion, even under
T Pfeifer et al.
Journal of mass spectrometry : JMS, 34(6), 644-650 (1999-07-08)
Mass spectrometric experiments with fragment ions have not yet been possible with a matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometer because intense signals of fragment ions were rarely observed during continuous extraction and the mass resolution of in-source formed fragment
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系客户支持