跳转至内容
Merck
CN

12086-U

金属填充GC色谱柱(常规配置)

phase none, matrix 80/100 HayeSep R support, L × O.D. × I.D. 6.0 ft (1.8 m) × 1/16 in. × 1.25 mm, Preconditioned

登录 查看组织和合同定价。

选择尺寸


关于此项目

UNSPSC Code:
41115710
NACRES:
SB.54
eCl@ss:
32119290
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助

material

stainless steel column

parameter

0-250 °C temperature (isothermal or programmed)

technique(s)

gas chromatography (GC): suitable

L × O.D. × I.D.

6.0 ft (1.8 m) × 1/16 in. × 1.25 mm, Preconditioned

matrix

80/100 HayeSep R support

matrix active group

none phase

column type

packed GC

compatibility

for use with General Configuration

正在寻找类似产品? 访问 产品对比指南

General description

对于不需要玻璃惰性的低要求应用,应使用经济型的金属柱。该色谱柱具有一般性配置,并可小心将其弯曲以适用于大多数仪器。
Packed column made up of stainless steel are basically employed when higher carrier gas flow rates are employed as they can sustain elevated pressure. Stainless steel columns are usually washed with dilute hydrochloric acid, then with water followed by methanol, acetone, methylene dichloride and n-hexane in order to remove any corrosion products and traces of lubricating agents. HayeSep R is suitable as the column packing material to act as a protective coating for the stationary phase.

Application

HayeSep R maybe used for packed column GC for quantitation of methanol, ethanol, isopropanol, acetone and ethylene glycol. It may also be used in studies investigating plasma stabilization of pre-mixed methane-air combustion using a miniaturized glide-arc reactor integrated into a Bunsen type burner for plasma-activation of fuel-steam mixtures.

Other Notes

This is a micropacked column. It is packed full and contains stainless steel screens.

This column is preconditioned.

法规信息

新产品
此项目有

历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 文件 section.

如需帮助,请联系 客户支持

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Glide-arc stabilization of lean methane-air combustion.
Hammer T, et al.
Proc. Int. Symp., 2 (2) (2008)
Introduction to Analytical Gas Chromatography.
Raymond PW.
Science, 102-108 (1997)
J F Livesey et al.
Clinical chemistry, 41(2), 300-305 (1995-02-01)
We developed a packed-column chromatographic procedure capable of simultaneous quantitation of methanol, ethanol, isopropanol, acetone, and ethylene glycol. This method was then updated to a rapid, sensitive, wide-bore capillary method. The packed-column system uses direct injection of 1 microL of

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系客户支持