物料
fused silica
Agency
meets requirements for USP G3
参数
0-250 °C temperature (isothermal or programmed)
β值
313
df
0.20 μm
技术
gas chromatography (GC): suitable
长度 × 内径
30 m × 0.25 mm
基质活性基团
Non-bonded; poly(50% phenyl/50% methyl siloxane) phase
色谱柱类型
capillary intermediate polar
正在寻找类似产品? 访问 产品对比指南
一般描述
Application: The SP-2250 column is a non-bonded 50% phenyl polymer. It is highly effective for the analysis of polar compounds.
USP Code: This column meets USP G3 requirements.
Phase:
USP Code: This column meets USP G3 requirements.
Phase:
- Non-bonded
- Poly(50% phenyl/50% methyl siloxane)
- 0 °C to 250 °C (isothermal or programmed)
应用
Capillary column coated with SP®-2250 (methyl silicone-phenyl silicone, 1:1) stationary phase may be used in gas chromatographic analysis of azaarenes (benzacridines and dibenzacridines).
其他说明
We offer a variety of chromatography accessories including analytical syringes
法律信息
SP is a registered trademark of Sigma-Aldrich Co. LLC
法规信息
新产品
此项目有
R Arendt et al.
Arzneimittel-Forschung, 32(4), 453-455 (1982-01-01)
Plasma concentrations of 5-(2-chlorophenyl)-7-ethyl-1,3-dihydro-1-methyl-2H-thieno[2,3-e][1,4]diazepin-2 -one (clotiazepam, CTZ, Trecalmo), a thienodiazepine anti-anxiety agent, and two of its metabolites (hydroxy- and desmethyl-clotiazepam) are reliably quantified by electron capture GLC. After addition of diazepam as internal standard, 1-ml plasma samples are extracted with
H B Hucker et al.
Journal of pharmaceutical sciences, 72(9), 1069-1070 (1983-09-01)
A method for the determination of cyproheptadine in plasma and urine was developed using the N -ethyl homologue as an internal standard. After extraction of the drug from an alkalinized sample into petroleum ether-isoamyl alcohol, back-extraction into 0.1 N HCl
K Nakamura et al.
Investigative ophthalmology & visual science, 31(10), 2059-2069 (1990-10-01)
Silicone oil (SiO) and fluorosilicone oil (FSiO) are useful in difficult cases of retinal detachment surgery. Unidentified low-molecular-weight components (LMWC) and residual catalysts in SiO and FSiO have been implicated in the adverse reactions of the oils in the eye.
D Courtot
British journal of sports medicine, 10(3), 143-146 (1976-10-01)
At the request of the Service des Haras, our laboratory works on the toxicological problems of the sport-horse. These studies have resulted in the setting up of an anti-doping control for equestrian competitions of various types, not only flat racing.
W Löscher
Therapeutic drug monitoring, 4(3), 315-318 (1982-01-01)
A rapid method was developed for the determination of diazepam, desmethyldiazepam, oxazepam, and 3-hydroxydiazepam (temazepam) in human plasma using electron capture gas chromatography. Following a single extraction with benzene from 0.2 ml plasma, diazepam and its metabolites were quantitated on
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系客户支持