物料
fused silica
Agency
meets requirements for USP G1, G2, and G9
参数
-60-320 °C temperature (isothermal or programmed)
β值
320
df
0.25 μm
技术
gas chromatography (GC): suitable
长度 × 内径
60 m × 0.32 mm
基质活性基团
Bonded; poly(dimethyl siloxane) phase
色谱柱类型
capillary non-polar
正在寻找类似产品? 访问 产品对比指南
一般描述
应用:该色谱柱被设计用于当需要非极性色谱柱时的传统通用用途应用。分析物将主要会根据沸点而被分离。
USP代码:该色谱柱满足USP G1、G2及G9要求。
固定相:
USP代码:该色谱柱满足USP G1、G2及G9要求。
固定相:
- 键合
- 聚(二甲基硅氧烷)
- ≤0.32 mm内径,<2 μm:-60°C至320°C (等温或程序性的)
- ≤0.32 mm内径,≥2 μm: -60°C至300°C (等温或程序性的)
- ≥0.53 mm内径, <2 μm: -60°C至300°C (等温)或320°C(程序性的)
- ≥0.53 mm内径, ≥2 μm: -60 °C至260 °C (等温)或280 °C(程序性的)
应用
SPB®-1 Capillary GC Column was used for speciation of the nitrogen compounds (quantitatively), which are polar and somewhat basic in nature, with chemiluminescence detection.
其他说明
We offer a variety of chromatography accessories including analytical syringes
法律信息
SPB is a registered trademark of Merck KGaA, Darmstadt, Germany
法规信息
新产品
此项目有
J M Jurado et al.
Talanta, 106, 14-19 (2013-04-20)
4-Methylsterols and 4,4-dimethylsterols of 47 samples of subcutaneous fat from Iberian pigs reared on two different fattening systems, "Extensive" and "Intensive", have been analyzed by GC-MS and GC-FID. The lipids were extracted by melting the subcutaneous fat in a microwave
V Gajdůsková et al.
Veterinarni medicina, 37(8), 471-478 (1992-08-01)
Occurrence of individual polychlorinated biphenyl (PCB) congeners in the environment, foodstuffs and other biological materials was assessed. Analysis of specific PCB congeners (28, 52, 101, 138, 153, 180), occurring in animal raw materials and foodstuffs most frequently, has been implemented.
O Suzuki et al.
Forensic science international, 46(3), 169-180 (1990-07-01)
Positive-ion electron impact (PIEI), positive-ion chemical ionization (PICI) and negative-ion chemical ionization (NICI) mass spectra of 9 carbamate pesticides are presented. In the PIEI mode, the spectra showed small molecular peaks, intense or base peaks due to M - CH3NHCO
Luisito Cercaci et al.
Journal of chromatography. A, 985(1-2), 211-220 (2003-02-13)
The sterol composition of extra virgin olive oil is very characteristic and, thus, has become a helpful tool to detect adulterations with other vegetable oils. Special attention has been addressed to the separate determination of the free and esterified sterol
Development of a passive sampler to measure personal exposure to gaseous PAHs in community settings.
Zhihua Fan et al.
Environmental science & technology, 40(19), 6051-6057 (2006-10-21)
A sensitive, simple, and cost-effective passive sampling methodology was developed to quantify personal exposure to gaseous polycyclic aromatic hydrocarbons (PAHs). A Fan-Lioy passive PAH sampler (FL-PPS) is constructed from 320 sections of 1-cm long SPB-5 GC columns (0.75-mm i.d. and
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系客户支持