SMILES string
C[Si](C)(Cl)Cl
InChI key
LIKFHECYJZWXFJ-UHFFFAOYSA-N
InChI
1S/C2H6Cl2Si/c1-5(2,3)4/h1-2H3
grade
derivatization grade ((GC derivatization))
description
Silyl reagent
packaging
pkg of 400 mL
concentration
5% dimethyldichlorosilane in toluene
General description
For deactivating glassware.
Treat the glass tubing that you use for columns with Sylon-CT solution (5% dimethyldichlorosilane in toluene). It deactivates the tubing for use up to 350 °C to 400 °C, far exceeding the capabilities of other deactivating agents used at room temperature. Sylon CT™ also deactivates transfer lines and glass or glass-lined injection port liners. Instructions included.
Treat the glass tubing that you use for columns with Sylon-CT solution (5% dimethyldichlorosilane in toluene). It deactivates the tubing for use up to 350 °C to 400 °C, far exceeding the capabilities of other deactivating agents used at room temperature. Sylon CT™ also deactivates transfer lines and glass or glass-lined injection port liners. Instructions included.
Application
Sylon CT™ was used as derivatizing agent, during an experiment to develop sensitive GC method for the identification and determination of long-chain primary alkyl amines. It was also used for treating Erlenmeyer flasks to prevent mycelium from sticking to the glassware during development of techniques in the identification and partial characterization the chaxamycin biosynthesis gene cluster of S. leeuwenhoekii.
Legal Information
Sylon CT is a trademark of Sigma-Aldrich Co. LLC
signalword
Danger
Hazard Classifications
Aquatic Chronic 3 - Asp. Tox. 1 - Eye Dam. 1 - Flam. Liq. 2 - Repr. 2 - Skin Corr. 1A - STOT RE 2 - STOT SE 3
target_organs
Central nervous system
supp_hazards
存储类别
3 - Flammable liquids
wgk
WGK 3
flash_point_f
39.2 °F - closed cup
flash_point_c
4 °C - closed cup
ppe
Faceshields, Gloves, Goggles, type ABEK (EN14387) respirator filter
法规信息
新产品
此项目有
Peter Kusch et al.
Journal of chromatography. A, 1113(1-2), 198-205 (2006-02-18)
Gas chromatography with simultaneous flame-ionization detection (FID) and a nitrogen-phosphorus detection (NPD) as well as gas chromatography-mass spectrometry (GC/MS) has been used to characterize long-chain primary alkyl amines after derivatization with trifluoroacetic anhydride (TFAA). Electron impact ionization- (EI) and negative
J M Curran et al.
Biomaterials, 32(21), 4753-4760 (2011-04-15)
Material modifications can be used to induce cell responses, in particular-CH(3) and -NH(2) have shown potential in enhancing the ability of a material to support mesenchymal stem cell (MSC) adhesion and differentiation. Currently this process is variable, due to the
[A multichannel microelectrode system for long-term use].
I F Kalmykov et al.
Fiziologicheskii zhurnal imeni I.M. Sechenova, 80(8), 135-138 (1994-08-01)
Teemu Näykki
Analytical and bioanalytical chemistry, 372(7-8), 829-831 (2002-05-16)
The use of silylation of glassware in mercury analytics was investigated. By treating the glassware with 5% (v/v) dichlorodimethylsilane in toluene, the surfaces of the vessels were inactivated. Method development proved that silylation can extend the range of stabile, contamination-free
Niels P Boks et al.
Microbiology (Reading, England), 154(Pt 10), 3122-3133 (2008-10-04)
Using a parallel-plate flow chamber, the hydrodynamic shear forces to prevent bacterial adhesion (F(prev)) and to detach adhering bacteria (F(det)) were evaluated for hydrophilic glass, hydrophobic, dimethyldichlorosilane (DDS)-coated glass and six different bacterial strains, in order to test the following
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系客户支持