40073

苯并[k]荧蒽 溶液

certified reference material, 1000 μg/mL in acetone

登录 查看组织和合同定价。

选择尺寸


关于此项目

经验公式(希尔记法):
C20H12
化学文摘社编号:
分子量:
252.31
PubChem Substance ID:
UNSPSC Code:
41116105
Beilstein/REAXYS Number:
1873745
MDL number:
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助

SMILES string

c1ccc2cc-3c(cc2c1)-c4cccc5cccc-3c45

InChI

1S/C20H12/c1-2-6-15-12-19-17-10-4-8-13-7-3-9-16(20(13)17)18(19)11-14(15)5-1/h1-12H

InChI key

HAXBIWFMXWRORI-UHFFFAOYSA-N

grade

certified reference material, TraceCERT®

product line

TraceCERT®

packaging

ampule of 1 mL

concentration

1000 μg/mL in acetone

technique(s)

HPLC: suitable, gas chromatography (GC): suitable

application(s)

environmental

format

single component solution

storage temp.

2-8°C

Application

Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.

Other Notes

This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.

Legal Information

TraceCERT is a registered trademark of Merck KGaA, Darmstadt, Germany

signalword

Danger

target_organs

Central nervous system

supp_hazards

存储类别

3 - Flammable liquids

wgk

WGK 3

flash_point_f

1.4 °F - closed cup

flash_point_c

-17 °C - closed cup

Hazard Classifications

Aquatic Chronic 3 - Carc. 1B - Eye Irrit. 2 - Flam. Liq. 2 - PBT - STOT SE 3 - vPvB

法规信息

危险化学品
易制毒化学品(3类)
此项目有

分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

K L Willett et al.
Toxicology and applied pharmacology, 177(3), 264-271 (2001-12-26)
Certainpolynuclear aromatic hydrocarbons (PAHs) such as benzo[a]pyrene (BaP) induce CYP1A-dependent enzyme activities. Because PAHs are ubiquitous environmental contaminants, and some are aryl hydrocarbon agonists, CYP1A has been used as a biomarker for PAH exposure. However, PAHs exist in the environment
Petra Booij et al.
Environmental toxicology and chemistry, 30(4), 898-904 (2010-12-31)
In bioassays, exposure concentrations of test compounds are usually expressed as nominal concentrations. As a result of various processes, such as adsorption, degradation, or uptake, the actual freely dissolved concentration of the test compound may differ from the nominal concentration.
Annekatrin Dreyer et al.
Environmental science & technology, 39(11), 3918-3924 (2005-06-30)
To date, studies about historic PAH (polycyclic aromatic hydrocarbons) deposition at a regional scale have rarely been published. To address this research gap, we sampled 17 ombrotrophic peatlands across eastern Canada. The peat cores from hollows were dated with 210Pb
Hiroyuki Masaki et al.
The Analyst, 130(9), 1253-1257 (2005-08-13)
We developed a device and some systems for detecting benzo[a]pyrene (B[a]P) and benzo[k]fluoranthene (B[k]F). The device uses a UV light-emitting diode that emits light with a wavelength of 370 nm and a violet laser diode that emits light with a
Erin E Bessette et al.
Drug metabolism and disposition: the biological fate of chemicals, 33(3), 312-320 (2004-12-04)
Polycyclic aromatic hydrocarbons (PAHs) and heavy metals are often environmental cocontaminants that could interact to alter PAH carcinogenicity. The heavy metal, arsenite, and the PAH, benzo[k]fluoranthene, were used as prototypes to investigate, in human HepG2 cells, mechanisms whereby the bioactivation

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系客户支持