等级
analytical standard
蒸汽密度
4.14 (vs air)
蒸汽压
2 mmHg ( 20 °C)
自燃温度
842 °F
expl. lim.
6 %
包装
ampule of 1000 mg
技术
HPLC: suitable
gas chromatography (GC): suitable
折射率
n20/D 1.491 (lit.)
沸点
159 °C (lit.)
mp
−99 °C (lit.)
密度
0.862 g/mL at 25 °C (lit.)
应用
environmental
包装形式
neat
储存温度
room temp
SMILES字符串
CCCc1ccccc1
InChI
1S/C9H12/c1-2-6-9-7-4-3-5-8-9/h3-5,7-8H,2,6H2,1H3
InChI key
ODLMAHJVESYWTB-UHFFFAOYSA-N
正在寻找类似产品? 访问 产品对比指南
应用
Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.
警示用语:
Danger
危险分类
Aquatic Chronic 2 - Asp. Tox. 1 - Flam. Liq. 3 - STOT SE 3
靶器官
Respiratory system
储存分类代码
3 - Flammable liquids
WGK
WGK 2
闪点(°F)
107.6 °F - closed cup
闪点(°C)
42.0 °C - closed cup
个人防护装备
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
法规信息
危险化学品
此项目有
Y C Shan et al.
Se pu = Chinese journal of chromatography, 19(3), 256-259 (2003-01-25)
A new method for predicting the retention time of solutes under linear gradient elution has been established. In this method, the migration distance of solutes in column and the mobile phase gradient were modified simultaneously according to the distribution of
Matthew Giardina et al.
Analytical chemistry, 75(7), 1604-1614 (2003-04-23)
With increasing interest in the detection of disease-related volatile organic compounds (VOCs) found in human breath, breath analysis could prove to be a very useful diagnostic tool, especially for the early detection of lung cancer. Solid-phase microextraction (SPME) is a
R Andrew Shalliker et al.
Journal of chromatography. A, 1216(5), 787-793 (2008-12-20)
The effect of solvent viscosity mismatch on elution performance in reversed-phase HPLC was studied using moment analysis. Two conditions were tested: (1) the mobile phase viscosity was less than the injection plug viscosity, and (2) the mobile phase viscosity was
Sara Eriksson et al.
Biodegradation, 16(3), 253-263 (2005-05-04)
The metabolism of monoaromatic hydrocarbons by an iron-reducing bacterial enrichment culture originating from diesel-contaminated groundwater was examined using d7-propylbenzene as a model hydrocarbon. Sequence analysis of the 16S rDNA gene showed that the dominant part (10 of 10 clones) of
S L Cruz et al.
British journal of pharmacology, 131(7), 1303-1308 (2000-11-23)
1. We have previously shown that toluene dose-dependently inhibits recombinant N-methyl-D-aspartate (NMDA) receptors at micromolar concentrations. This inhibition was rapid, almost complete and reversible. The NR1/2B combination was the most sensitive receptor subtype tested with an IC(50) value for toluene
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系客户支持