784630-U

Ascentis® Express 90 Å C18 PFAS (2 μm) HPLC Column

new

L × I.D. 10 cm × 3.0 mm, pk of 1 ea, suitable for PFAS testing

登录查看公司和协议定价

选择尺寸


技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助

物料

stainless steel column

质量水平

Agency

suitable for ASTM® 7968, 7979, 8421, 8535
suitable for CEN/TS 15968:2010
suitable for Centers for Disease Control 6304.09
suitable for DIN 38407-42, 38414-14, 17681-1, 17681-2
suitable for EPA 533, 537.1, 1621, 1633, 8327, OTM-45, OTM-50, ACB B21-02, ACB B23-05B, Plastic Container Method
suitable for GB 3106.35-2016, 5009.253-2016
suitable for HJ 1333-2023, 1334-2023
suitable for ISO 21675:2019, 25101, 23702-1
suitable for MoE E-3457
suitable for USDA CLG-PFAS 2.04
suitable for USP L1

管理合规性

suitable for FDA C-010.02, C-010.03

特点

endcapped

包装

pk of 1 ea

标记范围

7.2% Carbon loading

参数

1000 bar max. pressure (14500 psi)

长度 × 内径

10 cm × 3.0 mm

表面积

120 m2/g

基质

superficially porous particle particle platform

基质活性基团

bonding phase bonding phase bonding phase C18, extensively endcapped octadecylsilane (ODS) bonding phase

粒径

2 μm

孔径

90 Å pore size

工作pH范围

2-9 (60-40 °C)

应用

PFAS testing

分离技术

reversed phase

正在寻找类似产品? 访问 产品对比指南

一般描述

Ascentis® Express PFAS is a high-speed, high-performance liquid chromatography column based on the proven Fused-Core® particle design. This particle provides a thin porous shell of high-purity silica surrounding a solid silica core. The particle design exhibits very high column efficiency due to the shallow (0.4 μm) diffusion paths in the thick porous shell and the small overall particle size of 2 μm. The densely bonded, extensively endcapped ODS stationary phase of Ascentis® Express PFAS provides an application tested solution for PFAS analysis.
The Ascentis® Express PFAS HPLC column, with its Fused-Core® technology and a particle size of 2 µm, delivers fast and high resolution separations with excellent selectivity, peak shape, and necessary retention to perform in EPA methods 537.1, 533 and 8327.

特点和优势

  • 2 µm Fused-Core® particle for reliable and high efficiency separations, at lower column back pressure compared to porous 2 µm particles
  • Excellent suitability for MS detection
  • Application related Lot analysis and single column performance testing
  • Pressure limit: 1000 bar

分析说明

Target analytes include short chain and long chain per- and polyfluoroalkyl substances (PFAS), including branched and linear isomers.

其他说明

Column Care: To maximize column life,ensure that samples and mobile phases are particle-free. The use of an Ascentis® Express PFAS Delay column isrecommended to be placed before the sample injector to delay PFAS systemcontamination. Should the operating pressure of the column suddenly increasebeyond normal levels, reversing the flow direction of the column may beattempted to remove debris on the inlet frit. With 2 µm columns, reverse flow could bedetrimental to column performance and should be done carefully and at low flowrates. Exceeding half of the normal flow rate is not recommended. To remove strongly retainedmaterials from the column, flush the column in the reverse direction with verystrong solvents such as 100% of the organic component of the mobile phase inuse. A mixture (95/5 v/v) of dichloromethane and methanol is often effective atthis task. Extreme cases may require theuse of very strong solvents such as dimethylformamide (DMF) ordimethylsulfoxide (DMSO). Column Storage: Long-term storage ofsilica-based, reversed-phase columns is best in 100% acetonitrile. Columns may be safely stored for shortperiods (up to 3 or 4 days) in most common mobile phases. However, when using buffers, it is best toprotect both the column and the HPLC equipment and remove the salts by flushingthe column with the same mobile phase without the buffer (e.g., when using60/40 ACN/buffer, flush the columnwith 60/40 ACN/H2O) toeliminate any danger from corrosion from the salts while providing rapidre-equilibration of the column with the original mobile phase.Before storing the column,the end-fittings should be tightly sealed with the end-plugs that came with thecolumn to prevent the packing from drying.

法律信息

ASTM is a registered trademark of American Society for Testing and Materials
Ascentis is a registered trademark of Merck KGaA, Darmstadt, Germany
Fused-Core is a registered trademark of Advanced Materials Technology, Inc.