跳转至内容
Merck
CN
  • Serum creatinine and creatinine clearance for predicting plasma methotrexate concentrations after high-dose methotrexate chemotherapy for the treatment for childhood lymphoblastic malignancies.

Serum creatinine and creatinine clearance for predicting plasma methotrexate concentrations after high-dose methotrexate chemotherapy for the treatment for childhood lymphoblastic malignancies.

Cancer chemotherapy and pharmacology (2013-10-26)
Wei-qun Xu, Ling-yan Zhang, Xue-ying Chen, Bin-hua Pan, Jun-qing Mao, Hua Song, Jing-yuang Li, Yong-min Tang
摘要

Monitoring of plasma methotrexate (MTX) concentrations allows for therapeutic adjustments in treating childhood acute lymphoblastic leukemia (ALL) or non-Hodgkin lymphoma (NHL) with high-dose MTX (HDMTX). We tested the hypothesis that assessment of creatinine clearance (CrCl) and/or serum Cr may be a suitable means of monitoring plasma MTX concentrations. All children in the study had ALL or NHL, were in complete remission, and received HDMTX (3 or 5 g/m(2))+leucovorin. Plasma MTX concentrations were measured at 24, 48, and 96 h. CrCl was determined at 24 and 48 h. Correlations between 24- and 48-h plasma MTX concentrations and CrCl and serum Cr concentrations were determined. CrCl and serum Cr concentrations were compared over time between children who had delayed and non-delayed MTX elimination. A total of 105 children were included. There were significant negative correlations between CrCl at 24 and 48 h and plasma MTX concentrations at 24 (both p < 0.001) and 48 h (both p < 0.001). There were significant positive correlations between serum Cr concentrations at both 24 and 48 h and plasma MTX concentrations at 24 (both p < 0.001) and 48 h (both p < 0.001). There were 88 (30.2 %) instances of elimination delay. Children with elimination delay had significantly lower CrCl and higher Cr concentrations at 24 and 48 h compared with children without elimination delay (all p < 0.05). Our findings suggest that, with further refinement, assessment of renal function may be a useful means of monitoring plasma MTX concentrations during HDMTX for ALL and NHL.

材料
产品编号
品牌
产品描述

Sigma-Aldrich
甲氨蝶呤 水合物, ≥98% (HPLC), powder
Sigma-Aldrich
甲氨蝶呤 水合物, powder, BioReagent, suitable for cell culture, ≥98% (HPLC)
Sigma-Aldrich
甲氨蝶呤, meets USP testing specifications
Supelco
甲氨蝶呤,1 X 100MG 溶液, 1.0 mg/mL in methanol with 0.1N NaOH, ampule of 1 mL, certified reference material, Cerilliant®
甲氨蝶呤, European Pharmacopoeia (EP) Reference Standard
Sigma-Aldrich
甲氨蝶呤 水合物, ≥99.0% (sum of enantiomers, HPLC)
甲氨蝶呤, European Pharmacopoeia (EP) Reference Standard