跳转至内容
Merck
CN
  • Preliminary results of a new test for rapid diagnosis of septic arthritis with use of leukocyte esterase and glucose reagent strips.

Preliminary results of a new test for rapid diagnosis of septic arthritis with use of leukocyte esterase and glucose reagent strips.

The Journal of bone and joint surgery. American volume (2014-12-19)
Mohamed Omar, Max Ettinger, Moritz Reichling, Maximilian Petri, Ralf Lichtinghagen, Daniel Guenther, Eduardo M Suero, Michael Jagodzinski, Christian Krettek
摘要

Most currently used tools to diagnose septic arthritis are either not readily available or fail to provide real-time results. Reagent strip tests have identified infections in various body fluids. We hypothesized that combined leukocyte esterase and glucose strip tests can aid in diagnosing septic arthritis in native synovial fluid because (1) leukocyte esterase concentrations would be elevated at the infection site because of secretion by recruited neutrophils, and (2) glucose concentrations would be reduced because of bacterial metabolism. We prospectively investigated synovial fluid from consecutive patients with an atraumatic joint effusion who underwent arthrocentesis in our emergency department during a one-year period. Leukocyte esterase and glucose strip tests were performed on the synovial fluid. Synovial fluid leukocyte count, crystal analysis, Gram staining, culture, and glucose concentration results were also assessed. Nineteen fluids were classified as septic and 127 as aseptic. Considering septic arthritis to be present when the leukocyte esterase reading was positive (++ or +++) and the glucose reading was negative (-) yielded a sensitivity of 89.5% (95% confidence interval [CI], 66.9% to 98.7%), specificity of 99.2% (95% CI, 95.7% to 99.9%), positive predictive value of 94.4% (95% CI, 72.7% to 99.9%), negative predictive value of 98.4% (95% CI, 94.5% to 99.8%), positive likelihood ratio of 114, and negative likelihood ratio of 0.11. The synovial leukocyte counts and polymorphonuclear cell percentages were consistent with the semiquantitative readings on the leukocyte esterase strip tests, and the glucose concentrations were consistent with the glucose strip test results. Combined leukocyte esterase and glucose strip tests can be a useful additional tool to help confirm or rule out a diagnosis of septic arthritis.

材料
产品编号
品牌
产品描述

Sigma-Aldrich
D -(+)-葡萄糖, ≥99.5% (GC)
Sigma-Aldrich
D -(+)-葡萄糖, powder, BioReagent, suitable for cell culture, suitable for insect cell culture, suitable for plant cell culture, ≥99.5%
Sigma-Aldrich
D -(+)-葡萄糖 溶液, 45% in H2O, sterile-filtered, BioXtra, suitable for cell culture
Sigma-Aldrich
葡萄糖, 97.5-102.0% anhydrous basis, meets EP, BP, JP, USP testing specifications
Sigma-Aldrich
D -(+)-葡萄糖 溶液, 100 g/L in H2O, sterile-filtered, BioXtra, suitable for cell culture
Sigma-Aldrich
D -(+)-葡萄糖, ≥99.5% (GC), BioXtra
Supelco
葡萄糖, Pharmaceutical Secondary Standard; Certified Reference Material
USP
右旋糖, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
D -(+)-葡萄糖, BioUltra, anhydrous, ≥99.5% (sum of enantiomers, HPLC)
Sigma-Aldrich
D -(+)-葡萄糖, ACS reagent
Supelco
D -(+)-葡萄糖, analytical standard
Sigma-Aldrich
L - (−) -葡萄糖, ≥99%
Sigma-Aldrich
D -(+)-葡萄糖, suitable for mouse embryo cell culture, ≥99.5% (GC)
Sigma-Aldrich
D -(+)-葡萄糖, Hybri-Max, powder, BioReagent, suitable for hybridoma
Sigma-Aldrich
D -(+)-葡萄糖, tested according to Ph. Eur.
Sigma-Aldrich
D-葡萄糖-12C6, 16O6, 99.9 atom % 16O, 99.9 atom % 12C
Supelco
D -(+)-葡萄糖 溶液, 1 mg/mL in 0.1% benzoic acid, standard for enzymatic assay kits GAGO20, GAHK20, STA20, analytical standard
Sigma-Aldrich
D -(+)-葡萄糖, Vetec, reagent grade, ≥99.5% (HPLC)