  • Magnetic graphene - polystyrene sulfonic acid nano composite: A dispersive cation exchange sorbent for the enrichment of aminoalcohols and ethanolamines from environmental aqueous samples.

Magnetic graphene - polystyrene sulfonic acid nano composite: A dispersive cation exchange sorbent for the enrichment of aminoalcohols and ethanolamines from environmental aqueous samples.

Journal of chromatography. A (2015-11-12)
Sridhar Chinthakindi, Ajay Purohit, Varoon Singh, Vijay Tak, D K Dubey, Deepak Pardasani
摘要

Present study aimed at graphene surface modification to achieve selective analyte binding in dispersive solid phase extraction. Magnetic graphene - polystyrene sulfonic acid (MG-PSS) cation exchange nano-composite was prepared by non-covalent wrapping method. Composite was characterized by FT-IR and zeta potential. Material exhibited good dispersion in water and high exchange capacity of 1.97±0.16mMg(-1). Prepared nano-sorbent was then exploited for the cation exchange extraction and gas chromatography mass spectrometric analysis of Chemical Weapons Convention relevant aminoalcohols and ethanolamines from aqueous samples. Extraction parameters such as sorbent amount, extraction time, desorption conditions and sample pH were optimized and effect of common matrix interferences such as polyethylene glycol and metal salts was also studied. Three milligram of sorbent per mL of sample with 20min of extraction time at room temperature afforded 70-81% recoveries of the selected analytes spiked at concentration level of 1μgmL(-1). Method showed good linearity in the studied range with r(2)≥0.993. The limits of detection and limits of quantification ranged from 23 to 54ngmL(-1) and 72 to 147ngmL(-1), respectively. The relative standard deviation for intra- and inter-day precision ranged from 4.6 to 10.2% and 7.4 to 14.8% respectively. Applicability of the method to different environmental samples as well as the proficiency tests conducted by the Organization for the Prohibition of Chemical Weapons (OPCW) was also ascertained.

材料
产品编号
品牌
产品描述

Sigma-Aldrich
高锰酸钾, ACS reagent, ≥99.0%
Sigma-Aldrich
三乙基胺, ≥99.5%
Sigma-Aldrich
过硫酸钾, ACS reagent, ≥99.0%
Sigma-Aldrich
三乙基胺, ≥99%
Supelco
N,O-双(三甲基硅)三氟乙酰胺(含三甲基氯硅烷), with 1% trimethylchlorosilane, derivatization grade (GC derivatization), LiChropur
Sigma-Aldrich
三乙基胺, BioUltra, ≥99.5% (GC)
Sigma-Aldrich
三乙基胺, puriss. p.a., ≥99.5% (GC)
Sigma-Aldrich
N,O-双(三甲基硅基)三氟乙酰胺, ≥99%
Sigma-Aldrich
高锰酸钾, ACS reagent, ≥99.0%, low in mercury
Sigma-Aldrich
肼 一水合物, N2H4 64-65 %, reagent grade, ≥97%
Sigma-Aldrich
过氧化氢 溶液, contains ~200 ppm acetanilide as stabilizer, 3 wt. % in H2O
Sigma-Aldrich
肼 水合物, reagent grade, N2H4 50-60 %
Sigma-Aldrich
水合肼 溶液, puriss. p.a., 24-26% in H2O (RT)
Sigma-Aldrich
过氧化氢 溶液, contains inhibitor, 35 wt. % in H2O
Sigma-Aldrich
过硫酸钾, 99.99% trace metals basis
Sigma-Aldrich
高锰酸钾, 97%
Sigma-Aldrich
N,N-二乙基苯胺, ≥99%
Sigma-Aldrich
过氧化氢 溶液, 34.5-36.5%
Sigma-Aldrich
三乙基胺, for amino acid analysis, ≥99.5% (GC)
Sigma-Aldrich
三乙基胺, ampule, ≥99.5% (GC)
Sigma-Aldrich
高锰酸钾, puriss., meets analytical specification of Ph. Eur., BP, USP, 99-100.5%
Sigma-Aldrich
高锰酸钾, LR, ≥99%
Sigma-Aldrich
三乙醇胺, Vetec, reagent grade, 97%