登录 查看组织和合同定价。
选择尺寸
关于此项目
经验公式(希尔记法):
C20H14N2O3 · HCl
化学文摘社编号:
分子量:
366.80
UNSPSC Code:
12171500
NACRES:
NA.47
PubChem Substance ID:
EC Number:
236-944-7
Beilstein/REAXYS Number:
4631860
MDL number:
InChI key
JNGRENQDBKMCCR-UHFFFAOYSA-N
InChI
1S/C20H14N2O3.ClH/c21-11-5-7-15-17(9-11)25-18-10-12(22)6-8-16(18)19(15)13-3-1-2-4-14(13)20(23)24;/h1-10,21H,22H2,(H,23,24);1H
SMILES string
Cl.Nc1ccc2c(OC3=CC(=N)C=CC3=C2c4ccccc4C(O)=O)c1
form
powder or crystals
composition
Dye content, ≥75%
mp
>300 °C (lit.)
λmax
496 nm
application(s)
diagnostic assay manufacturing
hematology
histology
storage temp.
room temp
Quality Level
正在寻找类似产品? 访问 产品对比指南
General description
罗丹明110氯化物(R110)是一种激光级染料。
Application
罗丹明110氯化物已被用于合成罗丹明110十八烷基酯(R110C18)。
存储类别
11 - Combustible Solids
wgk
WGK 3
flash_point_f
Not applicable
flash_point_c
Not applicable
ppe
Eyeshields, Gloves, type N95 (US)
Thiemo Spielmann et al.
The journal of physical chemistry. B, 114(11), 4035-4046 (2010-03-04)
Triplet, photo-oxidized and other photoinduced, long-lived states of fluorophores are sensitive to the local environment and thus attractive for microenvironmental imaging purposes. In this work, we introduce an approach where these states are monitored in a total internal reflection (TIR)
Simeonika Rangełowa-Jankowska et al.
Chemphyschem : a European journal of chemical physics and physical chemistry, 12(13), 2449-2452 (2011-07-14)
The first observation of strong directional surface-plasmon-coupled emission (SPCE) of Rhodamine 110 in silica nanofilms deposited on silver nanolayers is reported. The preparation of the material is described in detail. The intensity of SPCE exceeds 10 times that of free
Ana Virel et al.
Analytical chemistry, 84(5), 2380-2387 (2012-02-14)
By site directed mutagenesis, we have produced recombinant mutants of human and mouse prethrombin-2 which are able to convert themselves autocatalytically into α-thrombin. We also have created a new method to amplify the signal of bioanalytical assays based on the
Marisa Ninivaggi et al.
Clinical chemistry, 58(8), 1252-1259 (2012-06-06)
The calibrated automated thrombogram (CAT) assay in plasma is a versatile tool to investigate patients with hypo- or hypercoagulable phenotypes. The objective was to make this method applicable for whole blood measurements. Thin-layer technology and the use of a rhodamine
Qi Chen et al.
Small (Weinheim an der Bergstrasse, Germany), 6(23), 2762-2768 (2010-11-13)
Temperature-induced vesicle-to-micelle transitions of polystyrene-block-poly acrylic acid (PS(139)-b-PAA(17)) aggregates in tetrahydrofuran (THF)/H(2)O solvent mixtures are studied. For a typical system with an initial concentration of PS(139)-b-PAA(17) of 2 wt% and 50 vol% of H(2)O, the morphology of the aggregates changes
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系客户支持