grade
certified reference material
manufacturer/tradename
Hellma 667-UV003
application(s)
food and beverages
petroleum
pharmaceutical
plastics
format
neat
正在寻找类似产品? 访问 产品对比指南
General description
Consisting of :
667-UV100 (see Z802425, for stray light)
667-UV200 (see Z802530, for spectral resolution)
667-UV305 (see Z802654, for photometric accuracy)
667-UV5 (see Z802328, for wavelength accuracy)
Wavelength [nm]:
A: 235; 257; 313; 350; 430
W: 241; 287; 361; 536; 640
S: 200 (cut-off)
R: Scan 265 - 270
This calibration set consists of eight liquid filters which enable the complete checking of the spectrophotometer according to European Pharmacopeia. They are designed for use with the standard 10 mm cell holder provided with spectrophotometers. The set is supplied in a sturdy wooden case. For identification purposes a number is engraved on each filter. The absorbance values and/or peak position wavelengths of every filter are quoted in the accompanying calibration certificate.
667-UV100 (see Z802425, for stray light)
667-UV200 (see Z802530, for spectral resolution)
667-UV305 (see Z802654, for photometric accuracy)
667-UV5 (see Z802328, for wavelength accuracy)
Wavelength [nm]:
A: 235; 257; 313; 350; 430
W: 241; 287; 361; 536; 640
S: 200 (cut-off)
R: Scan 265 - 270
This calibration set consists of eight liquid filters which enable the complete checking of the spectrophotometer according to European Pharmacopeia. They are designed for use with the standard 10 mm cell holder provided with spectrophotometers. The set is supplied in a sturdy wooden case. For identification purposes a number is engraved on each filter. The absorbance values and/or peak position wavelengths of every filter are quoted in the accompanying calibration certificate.
Application
Hellma® liquid calibration standards set for checking the wavelength accuracy, photometric accuracy, stray light, and spectral solution of spectrophotometers in accordance with European Pharmacopoeia (Ph. Eur.) and U.S. Pharmacopeia (USP) 857.
Features and Benefits
- Accredited to DAkkS Deutsche Akkreditierungsstelle (National accreditation body for the Federal Republic of Germany)
- Traceable to NIST (National Institute of Standards and Technology)
- Assured Quality of the measurement results
- Proven accuracy and reliability
Other Notes
The most current version of Hellma's handling guideslines for these calibration standards can be accessed on the Hellma Analytics web site.
Legal Information
Hellma is a registered trademark of Hellma GmbH
试剂盒组分也可单独购买
产品编号
说明
化学品安全说明书
- Z802328Hellma® liquid calibration standards, UV5, for testing the wavelength accuracy 1
- Hellma® liquid calibration standards set, UV1, UV12, for testing for stray light acc. to Ph. Eur. 1
- Z802530Hellma® liquid calibration standards set, UV6, UV9, for testing the spectral resolution acc. to Ph. Eur. 1
- Z802654Hellma® liquid calibration standards set, UV60, UV600, UV14, for testing the photometric accuracy 1
signalword
Danger
target_organs
Central nervous system, Nervous system
flash_point_f
-14.8 °F - closed cup
flash_point_c
-26.0 °C - closed cup
wgk
WGK 3
Hazard Classifications
Aquatic Chronic 2 - Asp. Tox. 1 - Eye Irrit. 2 - Flam. Liq. 2 - Ox. Liq. 2 - Repr. 2 - Skin Irrit. 2 - STOT RE 1 Inhalation - STOT SE 3
存储类别
5.1B - Oxidizing hazardous materials
法规信息
危险化学品
此项目有
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系客户支持