Computed gray levels in multislice and cone-beam computed tomography.

American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics (2013-07-03)
Fabiane Azeredo, Luciane Macedo de Menezes, Reyes Enciso, Andre Weissheimer, Rogério Belle de Oliveira
摘要

Gray level is the range of shades of gray in the pixels, representing the x-ray attenuation coefficient that allows for tissue density assessments in computed tomography (CT). An in-vitro study was performed to investigate the relationship between computed gray levels in 3 cone-beam CT (CBCT) scanners and 1 multislice spiral CT device using 5 software programs. Six materials (air, water, wax, acrylic, plaster, and gutta-percha) were scanned with the CBCT and CT scanners, and the computed gray levels for each material at predetermined points were measured with OsiriX Medical Imaging software (Geneva, Switzerland), OnDemand3D (CyberMed International, Seoul, Korea), E-Film (Merge Healthcare, Milwaukee, Wis), Dolphin Imaging (Dolphin Imaging & Management Solutions, Chatsworth, Calif), and InVivo Dental Software (Anatomage, San Jose, Calif). The repeatability of these measurements was calculated with intraclass correlation coefficients, and the gray levels were averaged to represent each material. Repeated analysis of variance tests were used to assess the differences in gray levels among scanners and materials. There were no differences in mean gray levels with the different software programs. There were significant differences in gray levels between scanners for each material evaluated (P <0.001). The software programs were reliable and had no influence on the CT and CBCT gray level measurements. However, the gray levels might have discrepancies when different CT and CBCT scanners are used. Therefore, caution is essential when interpreting or evaluating CBCT images because of the significant differences in gray levels between different CBCT scanners, and between CBCT and CT values.

材料
产品编号
品牌
产品描述

Sigma-Aldrich
Drierite, with indicator, 8 mesh
Sigma-Aldrich
Drierite, with indicator, 10-20 mesh
Sigma-Aldrich
硫酸钙 二水合物, ReagentPlus®, ≥99%
Sigma-Aldrich
硫酸钙, −325 mesh, 99%
Sigma-Aldrich
聚甲基丙烯酸甲酯, average Mw ~350,000 by GPC
Sigma-Aldrich
硫酸钙 半水合物, purum, ≥97.0%
Sigma-Aldrich
聚甲基丙烯酸甲酯
Sigma-Aldrich
硫酸钙 二水合物, ACS reagent, 98%
Sigma-Aldrich
聚甲基丙烯酸甲酯, average Mw ~15,000 by GPC, powder
Sigma-Aldrich
聚甲基丙烯酸甲酯
Sigma-Aldrich
硫酸钙, without indicator, 8 mesh
Sigma-Aldrich
硫酸钙, with indicator, 4 mesh
Sigma-Aldrich
硫酸钙, with indicator, 6 mesh
Sigma-Aldrich
硫酸钙 二水合物, puriss., meets analytical specification of NF, E 516, 99.0-101.0% (based on anhydrous substance)
Sigma-Aldrich
硫酸钙, ≥99.99% trace metals basis
Sigma-Aldrich
硫酸钙, without indicator, 4 mesh
Sigma-Aldrich
等规聚(甲基丙烯酸甲酯), >80% isotactic
Supelco
聚甲基丙烯酸甲酯, analytical standard, suitable for gel permeation chromatography (GPC), 2,000
Supelco
聚甲基丙烯酸甲酯, analytical standard, suitable for gel permeation chromatography (GPC), 100,000
Supelco
聚甲基丙烯酸甲酯, analytical standard, suitable for gel permeation chromatography (GPC), 50,000
Supelco
聚甲基丙烯酸甲酯, analytical standard, suitable for gel permeation chromatography (GPC), average Mw 97,000 (Typical), average Mn 46,000 (Typical)
Supelco
聚甲基丙烯酸甲酯, analytical standard, 2,480,000
Supelco
聚甲基丙烯酸甲酯, analytical standard, suitable for gel permeation chromatography (GPC), 4,000
Supelco
聚甲基丙烯酸甲酯, analytical standard, suitable for gel permeation chromatography (GPC), 10,000
Supelco
聚甲基丙烯酸甲酯, analytical standard, suitable for gel permeation chromatography (GPC), 20,000
Supelco
聚甲基丙烯酸甲酯, analytical standard, suitable for gel permeation chromatography (GPC), 8,000