Merck
CN
  • Serum 7 alpha-hydroxy-4-cholesten-3-one and selenohomocholyltaurine (SeHCAT) whole body retention in the assessment of bile acid induced diarrhoea.

Serum 7 alpha-hydroxy-4-cholesten-3-one and selenohomocholyltaurine (SeHCAT) whole body retention in the assessment of bile acid induced diarrhoea.

European journal of gastroenterology & hepatology (1996-02-01)
W G Brydon, H Nyhlin, M A Eastwood, M V Merrick
摘要

To assess the reliability of serum 7 alpha-hydroxy-4-cholesten-3-one (7 alpha-3ox-C) in the differential diagnosis of bile acid induced diarrhoea by comparison with 75selenohomocholyltaurine whole body retention (SeHCAT WBR). One hundred and sixty-four patients with chronic diarrhoea were investigated prospectively in two centres (Edinburgh and Sweden) by two different tests which measure bile acid loss or synthesis: the SeHCAT test which measures the 7-day SeHCAT WBR and serum 7 alpha-3ox-C which reflects the rate of bile acid synthesis. Forty-six patients had SeHCAT WBR of less than 10% (19 with ileal disease or resection, nine with idiopathic bile acid induced diarrhoea and 18 with miscellaneous causes for bile acid induced diarrhoea). All patients with ileal or idiopathic disease showed a favorable response to treatment as did 13 of the miscellaneous group. Serum 7 alpha-3ox-C was raised in all subjects with ileal disease/resection, seven patients with idiopathic disease and all subjects in the miscellaneous group who responded to treatment. Sixteen out of 118 patients with SeHCAT WBR greater than or equal to 10% had raised serum 7 alpha-3ox-C. The positive predictive value of serum 7 alpha-3ox-C was 74%. The high negative predictive value (98%) of serum 7 alpha-3ox-C indicates the possible use of this test for excluding bile acid malabsorption in this population. All but two subjects who responded to treatment had raised serum 7 alpha-3ox-C concentrations. The possibility that the sensitivity of the test can be improved by repeat testing needs to be further investigated. There was a significant correlation between fractional catabolic rate (FCR) SeHCAT and serum 7 alpha-3ox-C (r = 0.63, P < 0.0001). Further data are required to validate the reference range in women over 70 years of age.

材料
货号
品牌
产品描述

Sigma-Aldrich
纯乙醇, 200 proof, for molecular biology
Sigma-Aldrich
甲醇, suitable for HPLC, ≥99.9%
Sigma-Aldrich
丙酮, ACS reagent, ≥99.5%
Sigma-Aldrich
2-丙醇, suitable for HPLC, 99.9%
Sigma-Aldrich
2-丙醇, ACS reagent, ≥99.5%
Sigma-Aldrich
2-丙醇, for molecular biology, BioReagent, ≥99.5%
Sigma-Aldrich
甲醇, ACS reagent, ≥99.8%
Sigma-Aldrich
纯乙醇, 200 proof, anhydrous, ≥99.5%
Sigma-Aldrich
纯乙醇, 200 proof, ACS reagent, ≥99.5%
Sigma-Aldrich
丙酮, suitable for HPLC, ≥99.9%
Sigma-Aldrich
甲醇, anhydrous, 99.8%
Sigma-Aldrich
丙酮, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%
Sigma-Aldrich
纯乙醇, 200 proof, HPLC/spectrophotometric grade
Sigma-Aldrich
2-丙醇, anhydrous, 99.5%
Sigma-Aldrich
甲醇, HPLC Plus, ≥99.9%
Sigma-Aldrich
酒精, BioUltra, for molecular biology, ≥99.8%, (absolute alcohol, without additive, A15 o1)
Sigma-Aldrich
甲醇, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
乙醛, ACS reagent, ≥99.5%
Sigma-Aldrich
甲醇, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
纯乙醇, 200 proof, meets USP testing specifications
Sigma-Aldrich
纯乙醇, 190 proof, ACS spectrophotometric grade, 95.0%
Sigma-Aldrich
异丙醇, meets USP testing specifications
Sigma-Aldrich
烟酸, ≥98%
Sigma-Aldrich
甲醇, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
异丙醇, 70% in H2O
Sigma-Aldrich
乙醛, puriss. p.a., anhydrous, ≥99.5% (GC)
Sigma-Aldrich
2-丁酮, ACS reagent, ≥99.0%
Sigma-Aldrich
乙醇,变性, reagent grade
Sigma-Aldrich
酒精试剂, reagent grade
Supelco
酒精, standard for GC