  • Accuracy of iodine removal using dual-energy CT with or without a tin filter: an experimental phantom study.

Accuracy of iodine removal using dual-energy CT with or without a tin filter: an experimental phantom study.

Acta radiologica (Stockholm, Sweden : 1987) (2013-04-25)
Tatsuya Kawai, Mitsuru Takeuchi, Masaki Hara, Kazuya Ohashi, Hirochika Suzuki, Kiyotaka Yamada, Yuya Sugimura, Yuta Shibamoto
摘要

The effects of a tin filter on virtual non-enhanced (VNE) images created by dual-energy CT have not been well evaluated. To compare the accuracy of VNE images between those with and without a tin filter. Two different types of columnar phantoms made of agarose gel were evaluated. Phantom A contained various concentrations of iodine (4.5-1590 HU at 120 kVp). Phantom B consisted of a central component (0, 10, 25, and 40 mgI/cm(3)) and a surrounding component (0, 50, 100, and 200 mgI/cm(3)) with variable iodine concentration. They were scanned by dual-source CT in conventional single-energy mode and dual-energy mode with and without a tin filter. CT values on each gel at the corresponding points were measured and the accuracy of iodine removal was evaluated. On VNE images, the CT number of the gel of Phantom A fell within the range between -15 and +15 HU under 626 and 881 HU at single-energy 120 kVp with and without a tin filter, respectively. With attenuation over these thresholds, iodine concentration of gels was underestimated with the tin filter but overestimated without it. For Phantom B, the mean CT numbers on VNE images in the central gel component surrounded by the gel with iodine concentrations of 0, 50, 100, and 200 mgI/cm(3) were in the range of -19-+6 HU and 21-100 HU with and without the tin filter, respectively. Both with and without a tin filter, iodine removal was accurate under a threshold of iodine concentration. Although a surrounding structure with higher attenuation decreased the accuracy, a tin filter improved the margin of error.

材料
产品编号
品牌
产品描述

Sigma-Aldrich
琼脂糖, BioReagent, Molecular Biology, low EEO
Sigma-Aldrich
琼脂糖, Type I, low EEO
Sigma-Aldrich
锡, ≥99%, powder
Sigma-Aldrich
锡, powder, <150 μm, 99.5% trace metals basis
Sigma-Aldrich
琼脂糖, Low EEO
Sigma-Aldrich
琼脂糖, Low EEO, for Immunoelectrophoresis
Sigma-Aldrich
琼脂糖, Ultra-low Gelling Temperature, molecular biology grade
Sigma-Aldrich
琼脂糖, High EEO
Sigma-Aldrich
锡, nanopowder, <150 nm particle size (SEM), ≥99% trace metals basis
Sigma-Aldrich
锡, powder, <45 μm particle size, 99.8% trace metals basis
Sigma-Aldrich
琼脂糖, Molecular Biology
Sigma-Aldrich
琼脂糖, Ultra-low Gelling Temperature
Sigma-Aldrich
Sepharose 4B, 45-165 μm bead diameter
Sigma-Aldrich
锡, powder, -100 mesh, 99.99% trace metals basis
Sigma-Aldrich
琼脂糖, Type I-A, low EEO
Sigma-Aldrich
琼脂糖, Medium EEO, Molecular Biology
Sigma-Aldrich
锡, granular, 0.425-2.0 mm particle size, ≥99.5%, ACS reagent
Sigma-Aldrich
锡, shot, 99.999% trace metals basis
Sigma-Aldrich
琼脂糖, Type II-A, Medium EEO
Sigma-Aldrich
琼脂糖, For pulsed field electrophoresis running gel
Sigma-Aldrich
Sepharose 6B, 6% Beaded Agarose, 45-165 μm (wet), fractionation range 10,000-1,000,000 Da (dextrans)
Sigma-Aldrich
锡, wire, diam. 0.5 mm, 99.999% trace metals basis
Sigma-Aldrich
锡, foil, thickness 0.127 mm, 99.9%
Sigma-Aldrich
琼脂糖, Special High EEO
Sigma-Aldrich
琼脂糖, High Gelling Temperature
Sigma-Aldrich
锡, 99.8%, shot, 3 mm
Sigma-Aldrich
琼脂糖, Wide range, Molecular Biology
Sigma-Aldrich
锡, foil, thickness 0.5 mm, 99.998% trace metals basis
Sigma-Aldrich
琼脂糖, High EEO
Sigma-Aldrich
琼脂糖, Type IV, Special High EEO