  • Assessment of two extraction methods to determine pesticides in soils, sediments and sludges. Application to the Túria River Basin.

Assessment of two extraction methods to determine pesticides in soils, sediments and sludges. Application to the Túria River Basin.

Journal of chromatography. A (2015-01-13)
Ana Masiá, Karina Vásquez, Julián Campo, Yolanda Picó
摘要

Pressurized liquid extraction (PLE) and Quick, Easy, Cheap, Effective, Rugged and Safe (QuEChERS) extraction methods were optimized for the simultaneous determination of 50 pesticides in sediment, soils and sewage sludge. For QuEChERS development, several buffers and dispersive solid-phase extraction clean-up (dSPE) sorbents were tested. In the PLE method, several parameters affecting the extraction efficiency, such as organic solvent, amount of sample, cell size, temperature, pressure, static time, number of cycles and % of flush, as well as sorbent used for the on-line clean up, were also evaluated. PLE and QuEChERS were assessed and compared in obtained recoveries (33-89% versus 25-120%), number of pesticides for which recoveries are in the range of 80-100% (up to 13 versus up to 35) and cost of the approach. QuEChERS procedure was faster, cheaper and easier to perform. Recoveries were around 80% (at 50ngg(-1) d.w.) and the matrix effect was less than -20% using matrix-matched standard calibration curve for most of the analytes. The limits of quantification were between 0.1 and 10ngg(-1) (d.w.) except for alachlor and acetochlor. Repeatability and reproducibility were lower than 28% (%RSD, n=5). Soil, sediment and sludge samples, taken from the Túria River Basin, were analyzed by QuEChERS to determine pesticides. Chlorpyrifos (up to 65.3ngg(-1) d.w.) was the most frequent and at higher concentrations. Thiabendazole, imazalil, diazinon, pyriproxyfen, hexythiazox, carbofuran, isoproturon, terbuthylazine and terbumeton were also found in some samples.

材料
产品编号
品牌
产品描述

Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
甲醇, suitable for HPLC, ≥99.9%
Sigma-Aldrich
丙酮, ACS reagent, ≥99.5%
Sigma-Aldrich
甲醇, ACS reagent, ≥99.8%
Sigma-Aldrich
二氯甲烷, suitable for HPLC, ≥99.8%, contains amylene as stabilizer
Sigma-Aldrich
乙酸乙酯, ACS reagent, ≥99.5%
Sigma-Aldrich
乙酸, glacial, ACS reagent, ≥99.7%
Sigma-Aldrich
丙酮, suitable for HPLC, ≥99.9%
Sigma-Aldrich
甲醇, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
乙酸乙酯, suitable for HPLC, ≥99.7%
Sigma-Aldrich
二氯甲烷, contains 40-150 ppm amylene as stabilizer, ACS reagent, ≥99.5%
Sigma-Aldrich
乙酸, glacial, ReagentPlus®, ≥99%
Sigma-Aldrich
丙酮, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%
Sigma-Aldrich
二氯甲烷, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%, contains 50-150 ppm amylene as stabilizer
Sigma-Aldrich
硫酸镁, anhydrous, ReagentPlus®, ≥99.5%
Sigma-Aldrich
甲醇, HPLC Plus, ≥99.9%
Sigma-Aldrich
丙酮, Laboratory Reagent, ≥99.5%
Sigma-Aldrich
乙酸钠, anhydrous, ReagentPlus®, ≥99.0%
Sigma-Aldrich
乙酸乙酯, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%
Sigma-Aldrich
乙腈, ACS reagent, ≥99.5%
Sigma-Aldrich
二氯甲烷, anhydrous, ≥99.8%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
乙腈, anhydrous, 99.8%
Supelco
甲酸铵, eluent additive for LC-MS, LiChropur, ≥99.0%
Sigma-Aldrich
氧化铝, standard grade, Brockmann I, activated, basic
Sigma-Aldrich
乙酸钠, ACS reagent, ≥99.0%
Sigma-Aldrich
甲醇, anhydrous, 99.8%
Sigma-Aldrich
甲酸铵, reagent grade, 97%
Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
乙酸, glacial, ≥99.99% trace metals basis
Sigma-Aldrich
硫酸镁, anhydrous, reagent grade, ≥97%