跳转至内容
Merck
CN
  • Enhancement of specificity of aldosterone measurement in human serum and plasma using 2D-LC-MS/MS and comparison with commercial immunoassays.

Enhancement of specificity of aldosterone measurement in human serum and plasma using 2D-LC-MS/MS and comparison with commercial immunoassays.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2014-09-24)
Julie A Ray, Mark M Kushnir, John Palmer, Seyed Sadjadi, Alan L Rockwood, A Wayne Meikle
摘要

Accurate measurement of aldosterone is important for the standardized testing of primary hyperaldosteronism. Commercial immunoassays show substantial between-method variations resulting in significant clinical consequences. We developed a specific two dimensional (2D)-LC-MS/MS method for measuring aldosterone in human serum and plasma and compared it with three commercial immunoassays and an LC-MS/MS method. 250 μL samples, controls and calibrators spiked with d4-aldosterone were subjected to liquid-liquid extraction. The samples were analyzed using negative mode electrospray and 2D-LC followed by MS detection using an ABSciex 5500 mass spectrometer and compared with immunoassays of Siemens (Coat-A-Count), DiaSorin (CLIA-LIAISON), and IBL (ELISA). Data was acquired using multiple reaction-monitoring mode. LOQ and LOD of the method were 0.04 and 0.02 nmol/L respectively. The assay was linear up to 166 nmol/L. Inter and intra-assay imprecision at 0.13, 1.38 and 8.30 nmol/L were <10%. Interferences were absent and no differences were observed between serum and plasma matrices. Method recovery ranged from 95% to 113%. Ion suppression was not observed. Evaluated immunoassays showed positive biases ranging between 22% and 37% when compared with the developed method. We developed and validated an accurate method for measurement of aldosterone in human serum and plasma using 2D-LC-MS/MS which is suitable for clinical purposes. The method is faster than previously published LC-MS/MS methods, uses less sample, has adequate sensitivity while being able to preserve high specificity in a cost effective manner. Linearity of the assay makes it promising for urine and adrenal venous samples. Comparison with three commercial immunoassays demonstrates the advantages of the developed method.

材料
产品编号
品牌
产品描述

Sigma-Aldrich
甲醇, suitable for HPLC, ≥99.9%
Sigma-Aldrich
甲醇, ACS reagent, ≥99.8%
Sigma-Aldrich
甲醇, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
甲醇, HPLC Plus, ≥99.9%
Sigma-Aldrich
丁基甲基醚, suitable for HPLC, ≥99.8%
Sigma-Aldrich
乙酸铵, ACS reagent, ≥97%
Sigma-Aldrich
丁基甲基醚, ACS reagent, ≥99.0%
Sigma-Aldrich
甲醇, anhydrous, 99.8%
Sigma-Aldrich
丁基甲基醚, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%
Sigma-Aldrich
乙酸铵, ≥99.99% trace metals basis
Supelco
乙酸铵, LiChropur, eluent additive for LC-MS
Sigma-Aldrich
甲醇, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
甲醇, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
甲醇, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
甲醇, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
乙酸铵, Molecular Biology, ≥98%
Sigma-Aldrich
甲醇, ACS reagent, ≥99.8%
Sigma-Aldrich
丁基甲基醚, reagent grade, ≥98%
Sigma-Aldrich
乙酸铵 溶液, Molecular Biology, 7.5 M
Sigma-Aldrich
丁基甲基醚, anhydrous, 99.8%
USP
木精, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
甲醇, BioReagent, ≥99.93%
Sigma-Aldrich
丁基甲基醚, puriss. p.a., ≥99.5% (GC)
Supelco
甲醇, analytical standard
Sigma-Aldrich
乙酸铵, 99.999% trace metals basis
Supelco
甲醇, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
醛固酮, ≥95% (HPLC)
Sigma-Aldrich
甲醇, ACS reagent, ≥99.8%
Sigma-Aldrich
乙酸铵, reagent grade, ≥98%
Sigma-Aldrich
乙酸铵, BioXtra, ≥98%