跳转至内容
Merck
CN
  • Hydrophilic-interaction liquid chromatography-tandem mass spectrometric determination of erythrocyte 5-phosphoribosyl 1-pyrophosphate in patients with hypoxanthine-guanine phosphoribosyltransferase deficiency.

Hydrophilic-interaction liquid chromatography-tandem mass spectrometric determination of erythrocyte 5-phosphoribosyl 1-pyrophosphate in patients with hypoxanthine-guanine phosphoribosyltransferase deficiency.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2014-12-09)
Hiroshi Hasegawa, Yoshihiko Shinohara, Sayako Nozaki, Makiko Nakamura, Koei Oh, Osamu Namiki, Kiyotaka Suzuki, Akihiko Nakahara, Mari Miyazawa, Ken Ishikawa, Takahiro Himeno, Sayaka Yoshida, Takanori Ueda, Yasukazu Yamada, Kimiyoshi Ichida
摘要

Mutations in the gene encoding hypoxanthine-guanine phosphoribosyltransferase (HPRT) cause Lesch-Nyhan disease (LND) and its variants (LNV). Due to the technical problems for measuring the HPRT activity in vitro, discordances between the residual HPRT activity and the clinical severity were found. 5-Phosphoribosyl 1-pyrophosphate (PRPP) is a substrate for HPRT. Since increased PRPP concentrations were observed in erythrocytes from patients with LND and LNV, we have turned our attention to erythrocyte PRPP as a biomarker for the phenotype classification. In the present work, a method for determination of PRPP concentration in erythrocyte was developed using liquid chromatography-tandem mass spectrometry (LC-MS/MS) with multiple reaction monitoring (MRM). Packed erythrocyte samples were deproteinized by heating and the supernatants were injected into the LC-MS/MS system. All measurement results showed good precision with RSD <6%. PRPP concentrations of nine normal male subjects, four male patents with LND and six male patients with LNV were compared. The PRPP concentrations in erythrocyte from patients with LND were markedly increased compared with those from normal subjects, and those from patients with LNV were also increased but the degree was smaller than those with LND. The increase pattern of PRPP concentration in erythrocyte from patients with HPRT deficiency was consistent with the respective phenotypes and was correlated with the disease severity. PRPP concentration was suggested to give us supportive information for the diagnosis and the phenotype classification of LND and LNV.

材料
产品编号
品牌
产品描述

Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
乙腈, ACS reagent, ≥99.5%
Sigma-Aldrich
乙腈, anhydrous, 99.8%
Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
乙腈, ≥99.9% (GC)
Sigma-Aldrich
乙腈, suitable for HPLC-GC, ≥99.8% (GC)
Sigma-Aldrich
乙腈, biotech. grade, ≥99.93%
Sigma-Aldrich
乙腈, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
乙腈, suitable for DNA synthesis, ≥99.9% (GC)
Supelco
乙腈(纯品), Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
乙腈, analytical standard
Sigma-Aldrich
乙腈, ReagentPlus®, 99%
Sigma-Aldrich
乙腈, ≥99.5% (GC)
USP
二类残留溶剂 - 甲醇, United States Pharmacopeia (USP) Reference Standard
Supelco
残留溶剂标准品-乙腈(DMSO溶液), Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
氨-14N, 99.99 atom % 14N
Sigma-Aldrich
乙腈, Preparateur, ≥99.9% (GC), One-time steel-plastic (SP) drum