跳转至内容
Merck
CN
  • Evaluation of a LC-MS method for everolimus preclinical determination in brain by using [(13)C2D4]RAD001 internal standard.

Evaluation of a LC-MS method for everolimus preclinical determination in brain by using [(13)C2D4]RAD001 internal standard.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2015-02-16)
Stefano Giovagnoli, Tommaso Cassano, Lorenzo Pace, Alessandro Magini, Alice Polchi, Brunella Tancini, Marzia Perluigi, Federico De Marco, Carla Emiliani, Diego Dolcetta
摘要

Isotopic internal standards are increasingly frequent in LC-MS analysis to control biological matrix effects in the quantitation of immunosuppressant drugs, such as everolimus (RAD001). Here we present the evaluation of a LC-MS method, exploiting [(13)C2D4]RAD001 as internal standard, for preclinical determination of RAD001 in mice brain tissue. Samples were purified by solid phase extraction. Brain and blood were collected from vehicle-treated and RAD001-treated mice. The QTOF MS detector was set to select RAD001 ammonium adducts (m/z 975.6152) and [(13)C2D4]RAD001 (m/z 981.6481). Two different UHPLC columns were preliminarily tested. The method showed linear behavior between 4 and 100ng/mL (r(2)=0.99943) and linearity was preserved in the presence of blood (r(2)=0.99107) and brain (r(2)=0.99098) matrix components. Intra-day and inter-day precision (3-19%) and accuracy (82-109%) were comparable between standards and spiked blood and brain samples. As resulting from recovery comparison (82-98%), [(13)C2D4]RAD001 compensated ion suppression phenomena maintaining method performance over a wide range of consecutive analytical runs. The comparison with a HPLC-UV method showed reliability of the method with good correlation between blood (r(2)=0.94319) and brain (r(2)=0.97773) samples and acceptable biases (<15%). This validation suggests that the investigated method could be useful for the preclinical monitoring of RAD001 brain therapeutic concentrations in animal models.

材料
产品编号
品牌
产品描述

Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
甲醇, suitable for HPLC, ≥99.9%
Sigma-Aldrich
甲醇, ACS reagent, ≥99.8%
Sigma-Aldrich
甲醇, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
甲醇, HPLC Plus, ≥99.9%
Sigma-Aldrich
乙腈, ACS reagent, ≥99.5%
Sigma-Aldrich
乙腈, anhydrous, 99.8%
Supelco
甲酸铵, eluent additive for LC-MS, LiChropur, ≥99.0%
Sigma-Aldrich
甲醇, anhydrous, 99.8%
Sigma-Aldrich
甲酸铵, reagent grade, 97%
Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
乙腈, ≥99.9% (GC)
Sigma-Aldrich
甲醇, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
甲醇, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
甲醇, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
甲酸铵, ≥99.995% trace metals basis
Sigma-Aldrich
甲醇, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
甲醇, ACS reagent, ≥99.8%
Sigma-Aldrich
甲酸铵 溶液, BioUltra, 10 M in H2O
Sigma-Aldrich
乙腈, suitable for HPLC-GC, ≥99.8% (GC)
USP
木精, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
甲醇, BioReagent, ≥99.93%
Supelco
甲醇, analytical standard
Supelco
甲醇, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
甲酸铵, BioUltra, ≥99.0% (calc. based on dry substance, NT)
Sigma-Aldrich
乙腈, biotech. grade, ≥99.93%
Sigma-Aldrich
乙腈, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
甲醇, ACS reagent, ≥99.8%
Sigma-Aldrich
甲酸, ≥95%, FCC, FG
Sigma-Aldrich
乙腈, suitable for DNA synthesis, ≥99.9% (GC)