跳转至内容
Merck
CN
  • Rapid quantitative chiral amphetamines liquid chromatography-tandem mass spectrometry: method in plasma and oral fluid with a cost-effective chiral derivatizing reagent.

Rapid quantitative chiral amphetamines liquid chromatography-tandem mass spectrometry: method in plasma and oral fluid with a cost-effective chiral derivatizing reagent.

Journal of chromatography. A (2014-07-30)
Matthew N Newmeyer, Marta Concheiro, Marilyn A Huestis
摘要

Methamphetamine is a widely abused psychostimulant containing a chiral center. Consumption of over-the-counter and prescription medications may yield positive amphetamines results, but chiral separation of l- and d-methamphetamine and its metabolite amphetamine can help determine whether the source was licit or illicit. We present the first LC-MS/MS method with precolumn derivatization for methamphetamine and amphetamine chiral resolution in plasma and oral fluid collected with the Oral-Eze(®) and Quantisal™ devices. To 0.5mL plasma, 0.75mL Oral-Eze, or 1mL Quantisal specimen racemic d11-methamphetamine and amphetamine internal standards were added, followed by protein precipitation. Samples were centrifuged and supernatants loaded onto pre-conditioned Phenomenex(®) Strata™-XC Polymeric Strong Cation solid phase extraction columns. After washing, analytes were eluted with 5% ammonium hydroxide in methanol. The eluate was evaporated to dryness and reconstituted in water. Derivatization was performed with 1-fluoro-2,4-dinitrophenyl-5-l-alanineamide (Marfey's reagent) and heating at 45°C for 1h. Derivatized enantiomer separations were performed under isocratic conditions (methanol:water, 60:40) with a Phenomenex(®) Kinetex(®) 2.6μm C18 column. Analytes were identified and quantified by two MRM transitions and their ratio on a 3200 QTrap (AB Sciex) mass spectrometer in ESI negative mode. In all three matrices, the method was linear for all enantiomers from 1 to 500μg/L, with imprecision and accuracy of ≤11.3% and 85.3-108%, respectively. Extraction efficiencies ranged from 67.4 to 117% and matrix effects from -17.0 to 468%, with variation always ≤19.1%. Authentic plasma and OF specimens were collected from an IRB-approved study that included controlled Vicks(®) VapoInhaler™ administration. The present method is sensitive, selective, economic and rapid (separations accomplished in <10min), and improves methamphetamine result interpretation.

材料
产品编号
品牌
产品描述

Sigma-Aldrich
甲醇, suitable for HPLC, ≥99.9%
Sigma-Aldrich
丙酮, ACS reagent, ≥99.5%
Sigma-Aldrich
甲醇, ACS reagent, ≥99.8%
Sigma-Aldrich
氢氧化铵 溶液, ACS reagent, 28.0-30.0% NH3 basis
Sigma-Aldrich
乙酸, glacial, ACS reagent, ≥99.7%
Sigma-Aldrich
丙酮, suitable for HPLC, ≥99.9%
Sigma-Aldrich
甲醇, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
乙酸, glacial, ReagentPlus®, ≥99%
Sigma-Aldrich
丙酮, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%
Sigma-Aldrich
甲醇, HPLC Plus, ≥99.9%
Sigma-Aldrich
丙酮, Laboratory Reagent, ≥99.5%
Sigma-Aldrich
氢氧化铵 溶液, 28% NH3 in H2O, ≥99.99% trace metals basis
Sigma-Aldrich
甲醇, anhydrous, 99.8%
Sigma-Aldrich
乙酸, glacial, ≥99.99% trace metals basis
Sigma-Aldrich
乙酸 溶液, suitable for HPLC
Sigma-Aldrich
乙酸, glacial, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8%
Sigma-Aldrich
乙酸, glacial, puriss., meets analytical specification of Ph. Eur., BP, USP, 99.8-100.5%
Sigma-Aldrich
甲醇, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
甲醇, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
丙酮, suitable for HPLC, ≥99.8%
Sigma-Aldrich
丙酮, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.5% (GC)
Sigma-Aldrich
甲醇, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
氢氧化铵 溶液, puriss., 30-33% NH3 in H2O
Sigma-Aldrich
甲醇, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
甲醇, ACS reagent, ≥99.8%
Sigma-Aldrich
丙酮, ACS reagent, ≥99.5%
Sigma-Aldrich
氢氧化铵 溶液, puriss. p.a., reag. ISO, reag. Ph. Eur., ~25% NH3 basis
Supelco
丙酮, analytical standard
USP
木精, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
甲醇, BioReagent, ≥99.93%