跳转至内容
Merck
CN
  • In vitro performance of spacers for aerosol delivery during adult mechanical ventilation.

In vitro performance of spacers for aerosol delivery during adult mechanical ventilation.

Journal of aerosol medicine and pulmonary drug delivery (2014-07-23)
Nabile Boukhettala, Thierry Porée, Patrice Diot, Laurent Vecellio
摘要

During mechanical ventilation, different aerosol generators are employed with various interfaces. The objective of this study was to evaluate the performance of a range of spacers, including a new device called Combihaler® designed for connection with both nebulizers and pressurized Metered-Dose Inhalers (pMDIs). To assess the spacers, we used a ventilator and the Dual Adult Training and Test Lung (model 5600i, Michigan Instruments). Ventilation parameters were measured with and without spacers in volume-controlled and pressure-controlled mode. A filter was placed at the end of the endotracheal tube to measure aerosol delivery. Amikacin (1 g/8 mL) and salbutamol (5 mg/5 mL) were nebulized with an Aeroneb Solo® connected to its T-adapter or the Combihaler® spacer. Salbutamol (100 μg/actuation with 10 actuations) and beclomethasone (250 μg/actuation with 10 actuations) were delivered with a pMDI connected to a Minispacer®, an ACE® spacer, or a Combihaler® spacer. Drug delivery measurements were performed in volume-controlled mode in dry and humidified conditions. Drug deposits on the filter were assayed. The use of spacers and the T-adapter did not change the ventilation parameters (p>0.9). Aerosol delivery of salbutamol and Amikacin by nebulization increased up to three-fold with the Combihaler® compared with the T-adapter in humidified and nonhumidified conditions (p<0.05). Aerosol delivery of salbutamol and beclometasone by pMDI increased up to three-fold with the Combihaler® and the ACE® spacer compared with the Minispacer® in humidified and nonhumidified conditions (p<0.05). Aerosol delivery by pMDIs and vibrating mesh nebulizers using either a T-adapter or spacers was reduced by up to 62.5% in a humidified circuit compared with a nonhumidified circuit. Aerosol delivery via pMDIs and vibrating mesh nebulizers is greater with large spacers (Combihaler® and ACE®) than with smaller spacers (Minispacer®) or a T-adapter, in both humidified and nonhumidified conditions. In humidified conditions, the aerosol delivery decreased with all spacers.

材料
Product Number
品牌
产品描述

Sigma-Aldrich
水, suitable for HPLC
Sigma-Aldrich
水, Nuclease-Free Water, for Molecular Biology
Sigma-Aldrich
水, sterile-filtered, BioReagent, suitable for cell culture
Sigma-Aldrich
水, HPLC Plus
Sigma-Aldrich
氟化钠, ACS reagent, ≥99%
Sigma-Aldrich
水, Deionized
Supelco
水, suitable for ion chromatography
Sigma-Aldrich
水, for embryo transfer, sterile-filtered, BioXtra, suitable for mouse embryo cell culture
Sigma-Aldrich
水, Molecular Biology, sterile filtered
Sigma-Aldrich
氟化钠, ReagentPlus®, ≥99%
Supelco
水, for TOC analysis
Sigma-Aldrich
水, BioPerformance Certified
纯水密度标准物质RM, 0.9982 g/mL(20 °C), UKAS ISO/IEC17025 and ISO Guide 34 certified, density: 0.9982 g/mL at 20 °C, density: 0.9970 g/mL at 25 °C
Sigma-Aldrich
水, ACS reagent
Sigma-Aldrich
氟化钠, 99.99% trace metals basis
Supelco
水, for ultratrace analysis, ACS reagent
Supelco
氟化钠, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
水, for cell biology, sterile ultrafiltered
Sigma-Aldrich
氟化钠, anhydrous, powder, 99.99% trace metals basis
Sigma-Aldrich
氟化钠, puriss., meets analytical specification of Ph. Eur., BP, USP, 98.5-100.5% (calc. to the dried substance)
Sigma-Aldrich
水, PCR Reagent
Sigma-Aldrich
水, tested according to Ph. Eur.
Sigma-Aldrich
氟化钠, BioXtra, ≥99%
Sigma-Aldrich
氟化钠, BioReagent, suitable for insect cell culture, ≥99%
Sigma-Aldrich
氟化钠0.5M 溶液
Supelco
水, suitable for HPCE, suitable for luminescence, suitable for UV/Vis spectroscopy
Sigma-Aldrich
E-Toxate 水, endotoxin, free
Supelco
ISE用氟离子溶液, 0.1 M F-, for ion-selective electrodes
水, UKAS ISO/IEC17025 and ISO Guide 34 certified, density: 0.9982 g/mL at 20 °C, density: 0.9970 g/mL at 25 °C
Supelco
密度标准品 998kg/m3, H&D Fitzgerald Ltd. Quality