跳转至内容
Merck
CN
  • Comparison of methods for the analysis of therapeutic immunoglobulin G Fc-glycosylation profiles-Part 2: Mass spectrometric methods.

Comparison of methods for the analysis of therapeutic immunoglobulin G Fc-glycosylation profiles-Part 2: Mass spectrometric methods.

mAbs (2015-05-23)
Dietmar Reusch, Markus Haberger, David Falck, Britta Peter, Bernd Maier, Jana Gassner, Michaela Hook, Katharina Wagner, Lea Bonnington, Patrick Bulau, Manfred Wuhrer
摘要

To monitor the Fc glycosylation of therapeutic immunoglobulin G in bioprocess development, product characterization and release analytics, reliable techniques for glycosylation analysis are needed. Several analytical methods are suitable for this application. We recently presented results comparing detection methods for glycan analysis that are separation-based, but did not include mass spectrometry (MS). In the study reported here, we comprehensively compared MS-based methods for Fc glycosylation profiling of an IgG biopharmaceutical. A therapeutic antibody reference material was analyzed 6-fold on 2 different days, and the methods investigated were compared with respect to precision, accuracy, throughput and analysis time. Emphasis was put on the detection and quantitation of sialic acid-containing glycans. Eleven MS methods were compared to hydrophilic interaction liquid chromatography of 2-aminobenzamide labeled glycans with fluorescence detection, which served as a reference method and was also used in the first part of the study. The methods compared include electrospray MS of the heavy chain and Fc part after limited digestion, liquid chromatography MS of a tryptic digest, porous graphitized carbon chromatography MS of released glycans, electrospray MS of glycopeptides, as well as matrix assisted laser desorption ionization MS of glycans and glycopeptides. Most methods showed excellent precision and accuracy. Some differences were observed with regard to the detection and quantitation of low abundant glycan species like the sialylated glycans and the amount of artefacts due to in-source decay.

材料
产品编号
品牌
产品描述

Sigma-Aldrich
三 2-羰基乙基 磷盐酸盐 盐酸盐, powder
Sigma-Aldrich
纯乙醇, 200 proof, anhydrous, ≥99.5%
Supelco
三(2-羧乙基)膦 盐酸盐 溶液, 0.5 M, pH 7.0(aqueous solution; pH was adjusted with ammonium hydroxide)
Sigma-Aldrich
氯化钠, Molecular Biology, DNase, RNase, and protease, none detected, ≥99% (titration)
Sigma-Aldrich
氯化钠 溶液, 5 M in H2O, BioReagent, Molecular Biology, suitable for cell culture
Sigma-Aldrich
氯化钠, BioXtra, ≥99.5% (AT)
Sigma-Aldrich
氯化钠, BioReagent, suitable for cell culture, suitable for insect cell culture, suitable for plant cell culture, ≥99%
Sigma-Aldrich
氯化钠 溶液, 0.9% in water, BioXtra, suitable for cell culture
Sigma-Aldrich
纯乙醇, 190 proof, ACS spectrophotometric grade, 95.0%
Sigma-Aldrich
N-(3-二甲基氨基丙基)-N′-乙基碳二亚胺 盐酸盐, commercial grade, powder
Sigma-Aldrich
甲酸铵, ≥99.995% trace metals basis
Sigma-Aldrich
三 2-羰基乙基 磷盐酸盐 盐酸盐, BioUltra, ≥98% (NMR)
Sigma-Aldrich
N-(3-二甲基氨基丙基)-N′-乙基碳二亚胺 盐酸盐, ≥99.0% (AT)
Sigma-Aldrich
氯化钠 溶液, 5 M
Sigma-Aldrich
甲酸铵 溶液, BioUltra, 10 M in H2O
Sigma-Aldrich
N-(3-二甲基氨基丙基)-N′-乙基碳二亚胺 盐酸盐, crystalline
Sigma-Aldrich
2,5-二羟基苯甲酸, 98%
Sigma-Aldrich
纯乙醇, 190 proof, meets USP testing specifications
Sigma-Aldrich
氯化钠, BioUltra, Molecular Biology, ≥99.5% (AT)
Sigma-Aldrich
N-(3-二甲基氨基丙基)-N′-乙基碳二亚胺 盐酸盐, BioXtra
Sigma-Aldrich
氯化钠, meets analytical specification of Ph. Eur., BP, USP, 99.0-100.5%
Sigma-Aldrich
氯化钠 溶液, BioUltra, Molecular Biology, ~5 M in H2O
Sigma-Aldrich
氯化钠, 99.999% trace metals basis
Sigma-Aldrich
乙酸, suitable for luminescence, BioUltra, ≥99.5% (GC)
Supelco
2,5-二羟基苯甲酸, suitable for matrix substance for MALDI-MS, >99.0% (HPLC)
Sigma-Aldrich
甲酸, ≥95%, FCC, FG
Sigma-Aldrich
乙酸, ≥99.5%, FCC, FG
Sigma-Aldrich
乙酸, natural, ≥99.5%, FG
Sigma-Aldrich
氯化钠, BioPerformance Certified, ≥99% (titration), suitable for insect cell culture, suitable for plant cell culture
Sigma-Aldrich
氯化钠 溶液, 0.85%