跳转至内容
Merck
CN
  • Combined derivatization and high-performance liquid chromatography with fluorescence and ultraviolet detection for simultaneous analysis of octreotide and gabexate mesylate metabolite in human pancreatic juice samples.

Combined derivatization and high-performance liquid chromatography with fluorescence and ultraviolet detection for simultaneous analysis of octreotide and gabexate mesylate metabolite in human pancreatic juice samples.

Biomedical chromatography : BMC (2014-10-31)
Giuseppe Carlucci, Federico Selvaggi, Sara Sulpizio, Claudio Bassi, Maura Carlucci, Roberto Cotellese, Vincenzo Ferrone, Paolo Innocenti, Marcello Locatelli
摘要

A simple and sensitive method based on the combination of derivatization and high-performance liquid chromatography with ultraviolet and fluorimetric detection was developed for the simultaneous determination of octreotide and gabexate mesylate metabolite in human pancreatic juice samples. Parameters of the derivatization procedure affecting extraction efficiency were optimized. The developed method was validated according to the International Conference on Harmonization guidelines. The calibration curves were linear over a range of 0.1-15 µg/mL for octreotide and 0.20-15 µg/mL for gabexate mesylate metabolite. Derivatized products of octreotide and gabexate mesylate metabolite were separated on a Luna C18 column (4.6 × 250 mm; 5 µm particle size) using a gradient with a run time of 36 min, without further purification. The limits of detection were 0.025 and 0.05, respectively, for octreotide and gabexate mesylate metabolite. This paper reports the validation of a quantitative high performance liquid chromatography-photodiode array-fluorescence (HPLC-PDA-FL) method for the simultaneous analysis of octreotide and gabexate mesylate metabolite in pancreatic juice by protein precipitation using zinc sulfate-methanol-acetonitrile containing the derivatizing reagent, 4-fluoro-7-nitro-[2,1,3]-benzoxadiazole (NBD-F). Derivatized products of octreotide and gabexate mesylate metabolite were separated on a Luna C18 column (4.6 × 250 mm; 5 µm particle size) using a gradient with a run time of 36 min, without further purification. The method was validated over the concentration ranges 0.1-15 and 0.2-15 µg/mL for octreotide and gabexate mesylate metabolite, respectively, in human pancreatic juice. Biphalin and methyl-p-hydroxybenzoate were used as the internal standards. This method was successfully utilized to support clinical studies in humans. The results from assay validations show that the method is selective, sensitive and robust. The limit of quantification of the method was 0.1 µg/mL for octreotide and 0.2 µg/mL for gabexate mesylate metabolite, and matrix matched standard curves showed a good linearity up to 15 µg/mL. In the entire analytical range the intra- and inter-day precision (RSD%) values were respectively ≤5.9% and ≤3.1% for octreotide and ≤2.0% and ≤3.9% for gabexate mesylate metabolite. For both analytes the intra- and inter-day accuracy (bias) values ranged respectively from -6.8 to -2.5% and from -4.6 to -5.7%. This method utilizes derivatization with NBD-F and provides adequate sensitivity for both drugs.

材料
产品编号
品牌
产品描述

Sigma-Aldrich
乙腈, anhydrous, 99.8%
Sigma-Aldrich
甲醇, anhydrous, 99.8%
Sigma-Aldrich
盐酸 溶液, 1.0 N, BioReagent, suitable for cell culture
Sigma-Aldrich
邻苯二甲醛, ≥97% (HPLC), powder or crystals
Sigma-Aldrich
盐酸, 36.5-38.0%, BioReagent, Molecular Biology
Supelco
盐酸 溶液, volumetric, 0.1 M HCl (0.1N), endotoxin free
Sigma-Aldrich
4-羟基苯甲酸甲酯, ReagentPlus®, ≥99.0%, crystalline
Sigma-Aldrich
邻苯二甲醛, suitable for fluorescence, ≥99.0% (HPLC)
Sigma-Aldrich
盐酸 溶液, for amino acid analysis, ~6 M in H2O
Sigma-Aldrich
乙腈, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
邻苯二甲醛, suitable for HPLC fluorimetric detection of amino acids, ≥99% (HPLC), powder or crystals
Sigma-Aldrich
盐酸 溶液, 32 wt. % in H2O, FCC
Sigma-Aldrich
4-羟基苯甲酸甲酯, BioReagent, suitable for insect cell culture
Sigma-Aldrich
辛基膦酸, 97%
Sigma-Aldrich
4-羟基苯甲酸甲酯, ≥99%, FCC
Sigma-Aldrich
4-羟基苯甲酸甲酯, BioXtra, ≥99.0% (titration)
Sigma-Aldrich
甲醇, suitable for NMR (reference standard)
Sigma-Aldrich
4-羟基苯甲酸甲酯, analytical standard
Sigma-Aldrich
4-氟-7-硝基苯并-2-氧杂-1,3-二唑, ≥98% (elemental analysis)
Sigma-Aldrich
4-氟-7-硝基苯并-2-氧杂-1,3-二唑, suitable for fluorescence, BioReagent, ≥98.0% (HPLC)
Sigma-Aldrich
甲醇 溶液, contains 0.50 % (v/v) triethylamine
Sigma-Aldrich
甲醇, purification grade, 99.8%
Sigma-Aldrich
乙腈, Preparateur, ≥99.9% (GC), One-time steel-plastic (SP) drum