  • Application of a compact magnetic resonance imaging system for toxicologic pathology: evaluation of lithium-pilocarpine-induced rat brain lesions.

Application of a compact magnetic resonance imaging system for toxicologic pathology: evaluation of lithium-pilocarpine-induced rat brain lesions.

Journal of toxicologic pathology (2015-11-06)
Yoshikazu Taketa, Motohiro Shiotani, Yoshiharu Tsuru, Sadaharu Kotani, Yoshihide Osada, Tatsuto Fukushima, Akira Inomata, Satoru Hosokawa
摘要

Magnetic resonance imaging (MRI) is a useful noninvasive tool used to detect lesions in clinical and veterinary medicine. The present study evaluated the suitability of a new easy-to-use compact MRI platform (M2 permanent magnet system, Aspect Imaging, Shoham, Israel) for assisting with preclinical toxicologic pathology examination of lesions in the rat brain. In order to induce brain lesions, male Sprague-Dawley rats were treated once with lithium chloride (127 mg/kg, intraperitoneal [i.p.]) followed by pilocarpine (30 mg/kg, i.p.). One week after dosing, the perfused, fixed brains were collected, analyzed by the MRI system and examined histopathologically. MRI of the brain of treated rats revealed areas of high T1 and middle to low T2 signals, when compared with the controls, in the piriform cortex, lateral thalamic nucleus, posterior paraventricular thalamic nucleus and posterior hypothalamic nucleus of the cerebrum. The altered MRI signal areas were consistent with well-circumscribed foci of neuronal cell degeneration/necrosis accompanied by glial cell proliferation. The present data demonstrated that quick analysis of fixed organs by the MRI system can detect the presence and location of toxicologic lesions and provide useful temporal information for selection of appropriate sections for histopathologic examination before routine slide preparation, especially in complex and functionally heterogeneous organs such as the brain.

材料
Product Number
品牌
产品描述

Sigma-Aldrich
二甲基亚砜, Hybri-Max, sterile-filtered, BioReagent, suitable for hybridoma, ≥99.7%
Sigma-Aldrich
二甲基亚砜, ACS reagent, ≥99.9%
Sigma-Aldrich
二甲基亚砜, Molecular Biology
Sigma-Aldrich
二甲基亚砜, sterile-filtered, BioPerformance Certified, meets EP, USP testing specifications, suitable for hybridoma
Sigma-Aldrich
二甲基亚砜, ReagentPlus®, ≥99.5%
Sigma-Aldrich
二甲基亚砜, anhydrous, ≥99.9%
Sigma-Aldrich
氯化锂, ACS reagent, ≥99%
Sigma-Aldrich
二甲基亚砜, ≥99.5% (GC), suitable for plant cell culture
Sigma-Aldrich
二甲基亚砜, puriss. p.a., ACS reagent, ≥99.9% (GC)
Sigma-Aldrich
氯化锂, anhydrous, free-flowing, Redi-Dri, ReagentPlus®, 99%
Sigma-Aldrich
氯化锂, anhydrous, free-flowing, Redi-Dri, ACS reagent, ≥99%
Sigma-Aldrich
二甲基亚砜, BioUltra, Molecular Biology, ≥99.5% (GC)
Sigma-Aldrich
氯化锂, ReagentPlus®, 99%
Sigma-Aldrich
氯化锂 溶液, 8 M, Molecular Biology, ≥99%
Sigma-Aldrich
氯化锂, Molecular Biology, ≥99%
Sigma-Aldrich
L-赖氨酸 单盐酸盐, from non-animal source, meets EP, JP, USP testing specifications, suitable for cell culture, 98.5-101.0%
Sigma-Aldrich
过氧化氢 溶液, contains ~200 ppm acetanilide as stabilizer, 3 wt. % in H2O
Sigma-Aldrich
氯化锂, powder, ≥99.98% trace metals basis
Sigma-Aldrich
二甲基亚砜, meets EP testing specifications, meets USP testing specifications
Sigma-Aldrich
过氧化氢 溶液, contains inhibitor, 35 wt. % in H2O
Sigma-Aldrich
二甲基亚砜, PCR Reagent
Sigma-Aldrich
过氧化氢 溶液, 34.5-36.5%
Sigma-Aldrich
ApopTag过氧化物酶原位凋亡检测试剂盒, The ApopTag Peroxidase In Situ Apoptosis Detection Kit detects apoptotic cells in situ by labeling & detecting DNA strand breaks by the TUNEL method.
Sigma-Aldrich
二甲基亚砜, puriss. p.a., dried, ≤0.02% water
Sigma-Aldrich
L-赖氨酸 单盐酸盐, reagent grade, ≥98% (HPLC)
Sigma-Aldrich
氯化锂, BioXtra, ≥99.0% (titration)
Sigma-Aldrich
氯化锂, BioUltra, Molecular Biology, anhydrous, ≥99.0% (AT)
Sigma-Aldrich
氯化锂, puriss. p.a., anhydrous, ≥99.0% (AT)
Sigma-Aldrich
氯化锂, AnhydroBeads, −10 mesh, 99.998% trace metals basis
Sigma-Aldrich
L-赖氨酸 单盐酸盐, BioUltra, ≥99.5% (AT)