Skip to Content
Merck
CN

GCxGC Analysis of Allergens in Perfume Sample 1 on SLB®-5ms x SLB®-35ms, Non-Polar to Polar Strategy

GCxGC Analysis of Allergens in Perfume Sample 1 on SLB®-5ms x SLB®-35ms, Non-Polar to Polar Strategy suitable for GC

Materials

related product

Product No.
Description
Pricing

(R)-(+)-Limonene

analytical standard

(S)-(−)-Limonene

analytical standard

(+)-α-Terpineol

analytical standard

Terpinolene

technical, ≥85% (GC)

(+)-α-Pinene

analytical standard

(+)-β-Pinene

analytical standard

Benzaldehyde

analytical standard

Eugenol

PESTANAL®, analytical standard

(−)-Carvone

analytical standard

(+)-Carvone

analytical standard

trans-Anethole

analytical standard

Geraniol

analytical standard

Methyl salicylate

analytical standard

Salicylaldehyde

analytical standard

Phenethyl 2-methylbutyrate

≥95%, FG

Citronellol

≥95%, FCC, FG

(R)-(+)-β-Citronellol

95%

(S)-(−)-β-Citronellol

≥97%

1,3,4,6,7,8-Hexahydro-4,6,6,7,8,8-hexamethylcyclopenta[g]-2-benzopyran solution

in diethyl phthalate

β-Bromostyrene

97%

Anisyl alcohol

≥98%, FCC, FG

Anisyl alcohol

natural, ≥98%, FG

Cinnamaldehyde

natural, ≥95%, FG

Benzyl alcohol solution

certified reference material, 2000 μg/mL in methylene chloride

Damascenone

natural, 1.1-1.4 wt. % (190 proof ethanol), FG

Isoeugenol

analytical standard

SLB®-5ms Capillary GC Column

L × I.D. 20 m × 0.18 mm, df 0.18 μm

Linalool

analytical standard

Hydroxycitronellal

analytical standard

α-Hexylcinnamaldehyde

analytical standard

Farnesol

stabilized, analytical standard, mixture of isomers

Citral

analytical standard

Linalyl acetate

analytical standard

Cinnamyl alcohol

analytical standard

Benzyl benzoate

analytical standard

Linalool

certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

α-Amylcinnamaldehyde

mixture of cis and trans, analytical standard

Coumarin

certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

DL-Menthol

analytical standard

Benzyl salicylate

analytical standard

Methyl 2-octynoate

analytical standard

4-(4-Hydroxy-4-methylpentyl)-3-cyclohexene-1-carboxaldehyde

mixture of isomers, analytical standard

Vanillin

certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

(−)-Caryophyllene oxide

analytical standard

α-Damascone

analytical standard

(E)-β-Damascone

≥95%, sum of isomers, FG

Sclareol

analytical standard

δ-Damascone

analytical standard

3-Propylidenephthalide

mixture of isomers, analytical standard

6-Methylcoumarin

analytical standard

Santalol, α- and β-isomers

analytical standard

α−Isomethyl ionone

≥95%, stabilized, FG

Amyl salicylate

analytical standard

3-Methyl-5-(2,2,3-trimethyl-3-cyclopenten-1-yl)-4-penten-2-ol

analytical standard

CONDITIONS

column

(1D) SLB-5ms, 20 m x 0.18 mm I.D., 0.18 μm (28564-U)

column

(2D) SLB-35ms, 5 m x 0.25 mm I.D., 0.25 μm (29804-U)

oven

(1D) 45 °C, 3 °C/min to 230 °C

oven

(2D) 50 °C, 3 °C/min to 230 °C

oven

(modulator) stainless steel accumulation loop measuring 20 cm x 0.71 mm O.D. x 0.51 mm I.D.; modulation period 5.4 sec (accumulation period 4.9 sec; injection period 0.5 sec)

detector

qMS; ionization mode: electron ionization (70 eV); interface and ion source temperatures: 250 °C and 200 °C, respectively; mass range: 40-360 m/z; scan frequency: 25 Hz;

carrier gas

helium, initial inlet pressure: 130.8 kPa; initial auxiliary pressure: 65.2 kPa; in both dimensions the linear velocity was maintained constant

Description

Analysis Note

Data provided by Flavio A. Franchina (1), Mariasora Maimone (2), and Luigi Mondello (1,2) of (1) Chromaleont s.r.l., c/o “Scienze del Farmaco e Prodotti per la Salute” Department, University of Messina, viale Annunziata, 98168 Messina, Italy or (2) “Scienze del Farmaco e Prodotti per la Salute” Department, University of Messina, viale Annunziata, 98168 Messina, Italy.

The chromatogram shown here represents research toward the development of a flow-modulation comprehensive 2D GC/MS (FM GCxGC/MS) method for the determination of recently indicated allergens in fragrances. The detector was a rapid-scanning single quadrupole MS (quadMS). SLB-5ms and SLB-35ms GC columns were used. Mass spectral matching was carried out by using the FFNSC database.

Peak ID:
1. α-Pinene
3. β-Pinene
4. Limonene
7. Terpinolene
8. Linalool
9. Camphor
13. α-Terpineol
17. Linalyl Acetate
20. Geraniol
21. Geranial (Citral component)
24. Hydroxycitronellal
29. Eugenol
39. α-Isomethyl Ionone
47. Tetramethyl Acetyloctahydronaphthalenes

Legal Information