产品名称
Iotrolan, European Pharmacopoeia (EP) Reference Standard
InChI key
XUHXFSYUBXNTHU-UHFFFAOYSA-N
SMILES string
Ic1c(c(c(c(c1C(=O)NC(C(O)CO)CO)I)C(=O)NC(C(O)CO)CO)I)N(C)C(=O)CC(=O)N(C)c2c(c(c(c(c2I)C(=O)NC(C(O)CO)CO)I)C(=O)NC(C(O)CO)CO)I
InChI
1S/C37H48I6N6O18/c1-48(32-28(40)22(34(64)44-12(4-50)16(58)8-54)26(38)23(29(32)41)35(65)45-13(5-51)17(59)9-55)20(62)3-21(63)49(2)33-30(42)24(36(66)46-14(6-52)18(60)10-56)27(39)25(31(33)43)37(67)47-15(7-53)19(61)11-57/h12-19,50-61H,3-11H2,1-2H3,(H,44,64)(H,45,65)(H,46,66)(H,47,67)
grade
pharmaceutical primary standard
API family
iotrolan
manufacturer/tradename
EDQM
application(s)
pharmaceutical (small molecule)
format
neat
storage temp.
2-8°C
正在寻找类似产品? 访问 产品对比指南
Application
Iotrolan EP Reference standard, intended for use in laboratory tests only as specifically prescribed in the European Pharmacopoeia.
General description
This product is provided as delivered and specified by the issuing Pharmacopoeia. All information provided in support of this product, including SDS and any product information leaflets have been developed and issued under the Authority of the issuing Pharmacopoeia.For further information and support please go to the website of the issuing Pharmacopoeia.
Other Notes
Sales restrictions may apply.
Packaging
The product is delivered as supplied by the issuing Pharmacopoeia. For the current unit quantity, please visit the EDQM reference substance catalogue.
Kazuhiro Tsuchiya et al.
European radiology, 13(6), 1438-1443 (2003-05-24)
The advent of a multi-detector row helical CT has made it possible to attain images over a broader area with good spatial resolution. We assessed whether postmyelographic CT scans obtained using this system provided more information than conventional imaging techniques.
W Krause et al.
Investigative radiology, 37(12), 698-705 (2002-11-26)
Use of near-infrared reflection spectroscopy (NIR-RS) as a new model to assess renal tolerance of contrast agents and determination of the effects of a prostacyclin analogue and of two phosphodiesterase inhibitors on renal tolerance. NIR-RS was used to measure total
Xenophon Papacharalampous et al.
European journal of radiology, 55(3), 426-430 (2005-09-01)
To examine the effect of intra-articular injection of contrast media, sorbitol and normal saline on the synovial membrane. Sixty three rabbits (126 knees) were used in this study. We injected the knees with amidotrizoate, ioxaglate, iopamidol, iotrol and diluted gadolinium-DTPA
Xavier Montet et al.
Surgical and radiologic anatomy : SRA, 27(5), 444-449 (2005-09-01)
The aim of this study was to compare the intra-articular volumes of the wrist's joint measured by CT-arthrography and by dissection on ten cadavers. A good correlation was found between CT-arthrography and dissection in the assessment of the intra-articular volume
Werner Krause et al.
Investigative radiology, 38(11), 704-711 (2003-10-21)
To develop a new animal model for the evaluation of the renal tolerance of contrast agent and its application to diatrizoate and iotrolan injections in comparison to saline and mannitol solution. The nephrotoxic potential of intravenously injected contrast agents in
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系客户支持