跳转至内容
Merck
CN
  • Metrological traceability in mass spectrometry-based targeted protein quantitation: a proof-of-principle study for serum apolipoproteins A-I and B100.

Metrological traceability in mass spectrometry-based targeted protein quantitation: a proof-of-principle study for serum apolipoproteins A-I and B100.

Journal of proteomics (2014-06-28)
Nico P M Smit, Fred P H T M Romijn, Irene van den Broek, Jan W Drijfhout, Martin Haex, Arnoud van der Laarse, Yuri E M van der Burgt, Christa M Cobbaert
摘要

In this study, we have followed up on previous liquid chromatography (LC) multiple reaction monitoring (MRM) mass spectrometry (MS) approaches for measurement of apolipoprotein (apo) A-I and apo B100 in serum aiming for implementation of a multiplexed assay in a clinical chemistry laboratory with full metrological traceability. Signature peptides were selected and detected by dynamic MRM, and stable isotope labeled (SIL)-peptides were used as internal standards. Five apo A-I and four apo B100 peptides were measured in serum digests with linearity (R(2)>0.992) in the physiologically relevant concentration ranges. Linearity with regard to protein concentration was ascertained at five concentration levels (R(2)>0.926 and R(2)>0.965, for the apo A-I and apo B100 peptides, respectively). Three native value-assigned sera were used as external calibrators for further method verification. Imprecision values on sample preparation and LC-MS/MS acquisition were below the established minimal specifications for apo A-I and apo B100 (5.0% and 5.3%, respectively). Correlation of LC-MS/MS results with immunoturbidimetric assay results, for normo- and hypertriglyceridemic samples, showed R(2)>0.944 for apo A-I and R(2)>0.964 for apo B100. This LC-MS/MS method has potential for clinical application in normo- and dyslipidemic patients. Measurement of apo A-I and apo B100 may offer an alternative to high and low density lipoprotein cholesterol (HDL-c and LDL-c) methods for cardiovascular disease risk assessment in dyslipidemic patients [1]. An LC-MS/MS method for apo A-I and apo B100 has the advantage of antibody independent and specific detection of protein signature peptides. The introduction of an LC-MS/MS method for apo A-I and apo B100 can serve as an example for many existing and newly developed (multiplex) biomarker methods in quantitative clinical chemistry proteomics (qCCP). Such LC-MS/MS methods should meet basic clinical chemistry principles with regard to test evaluation [2]. Criteria for imprecision should be pre-defined, e.g., based on biological variation. The use of commutable and traceable serum-based calibrators will improve inter-laboratory reproducibility of LC-MS/MS methods and may contribute to a more rapid transition of biomarker discovery to clinical utility with benefit for the patient treatment and improvement of general health care.

材料
Product Number
品牌
产品描述

Sigma-Aldrich
甲醇, suitable for HPLC, ≥99.9%
Sigma-Aldrich
甲醇, ACS reagent, ≥99.8%
Sigma-Aldrich
甲醇, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
甲酸, reagent grade, ≥95%
Sigma-Aldrich
甲醇, HPLC Plus, ≥99.9%
Sigma-Aldrich
甲酸, ACS reagent, ≥96%
Sigma-Aldrich
碳酸氢铵, ReagentPlus®, ≥99.0%
Sigma-Aldrich
DL-二硫苏糖醇, Molecular Biology, ≥98% (HPLC), ≥99% (titration)
Sigma-Aldrich
甲醇, anhydrous, 99.8%
Sigma-Aldrich
2,2,2-三氟乙醇, ReagentPlus®, ≥99%
Sigma-Aldrich
碘乙酰胺, BioUltra
Sigma-Aldrich
DL-二硫代苏糖醇 溶液, BioUltra, Molecular Biology, ~1 M in H2O
Sigma-Aldrich
碘乙酰胺, Single use vial of 56 mg
Sigma-Aldrich
尿素, powder, BioReagent, Molecular Biology, suitable for cell culture
Sigma-Aldrich
DL-二硫苏糖醇, ≥98% (HPLC), ≥99.0% (titration)
Supelco
DL-二硫代苏糖醇 溶液, 1 M in H2O
Sigma-Aldrich
碘乙酰胺, ≥99% (NMR), crystalline
Sigma-Aldrich
甲醇, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
甲醇, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
甲醇, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
尿素, ACS reagent, 99.0-100.5%
Sigma-Aldrich
L-亮氨酸, from non-animal source, meets EP, JP, USP testing specifications, suitable for cell culture, 98.5-101.0%
Sigma-Aldrich
DL-二硫苏糖醇, BioUltra, Molecular Biology, ≥99.5% (RT)
Sigma-Aldrich
3-吲哚乙酸, 98%
Sigma-Aldrich
甲醇, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
甲醇, ACS reagent, ≥99.8%
Supelco
尿素, 8 M (after reconstitution with 16 mL high purity water)
Sigma-Aldrich
L-亮氨酸, reagent grade, ≥98% (HPLC)
Sigma-Aldrich
DL-二硫苏糖醇, ≥99.0% (RT)
Sigma-Aldrich
尿素 溶液, BioUltra, ~8 M in H2O