跳转至内容
Merck
CN
  • Flow injection combined with ICP-MS for accurate high throughput analysis of elemental impurities in pharmaceutical products according to USP <232>/<233>.

Flow injection combined with ICP-MS for accurate high throughput analysis of elemental impurities in pharmaceutical products according to USP <232>/<233>.

Journal of pharmaceutical and biomedical analysis (2014-03-29)
Lisa Fischer, Barbara Zipfel, Gunda Koellensperger, Jessica Kovac, Susanne Bilz, Andrea Kunkel, Cornel Venzago, Stephan Hann
摘要

New guidelines of the United States Pharmacopeia (USP), European Pharmacopeia (EP) and international organization (ICH, International Conference on Harmonization) regulating elemental impurity limits in pharmaceuticals seal the end of unspecific analysis of metal(oid)s as outlined in USP <231> and EP 2.4.8. Chapter USP <232> and EP 5.20 as well as drafts from ICH Q3D specify both daily doses and concentration limits of metallic impurities in pharmaceutical final products and in active pharmaceutical ingredients (API) and excipients. In chapters USP <233> and EP 2.4.20 method implementation, validation and quality control during the analytical process are described. By contrast with the--by now--applied methods, substance specific quantitative analysis features new basic requirements, further, significantly lower detection limits ask for the necessity of a general changeover of the methodology toward sensitive multi element analysis by ICP-AES and ICP-MS, respectively. A novel methodological approach based on flow injection analysis and ICP-SFMS/ICP-QMS for the quick and accurate analysis of Cd, Pb, As, Hg, Ir, Os, Pd, Pt, Rh, Ru, Cr, Mo, Ni, V, Cu, Mn, Fe and Zn in drug products by prior dilution, dissolution or microwave assisted closed vessel digestion according to the regulations is presented. In comparison to the acquisition of continuous signals, this method is advantageous with respect to the unprecedented high sample throughput due to a total analysis time of approximately 30s and the low sample consumption of below 50 μL, while meeting the strict USP demands on detection/quantification limits, precision and accuracy.

材料
产品编号
品牌
产品描述

Sigma-Aldrich
硝酸, ACS reagent, 70%
Sigma-Aldrich
硝酸, 70%, purified by redistillation, ≥99.999% trace metals basis
Sigma-Aldrich
L -抗坏血酸, powder, suitable for cell culture, γ-irradiated
Sigma-Aldrich
L -抗坏血酸, BioXtra, ≥99.0%, crystalline
Sigma-Aldrich
L -抗坏血酸, suitable for cell culture, suitable for plant cell culture, ≥98%
Sigma-Aldrich
硝酸, puriss. p.a., 65.0-67.0%
Sigma-Aldrich
L -抗坏血酸, 99%
Sigma-Aldrich
L -抗坏血酸, reagent grade, crystalline
Supelco
维生素C, Pharmaceutical Secondary Standard; Certified Reference Material
USP
抗坏血酸, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
L-丝氨酸, ReagentPlus®, ≥99% (HPLC)
Sigma-Aldrich
L-丝氨酸, from non-animal source, meets EP, USP testing specifications, suitable for cell culture, 98.5-101.0%
Sigma-Aldrich
硫脲, ACS reagent, ≥99.0%
Sigma-Aldrich
硝酸, puriss. p.a., reag. ISO, reag. Ph. Eur., ≥65%
Sigma-Aldrich
L -抗坏血酸, ACS reagent, ≥99%
Supelco
L -抗坏血酸, analytical standard
Sigma-Aldrich
硫脲, ReagentPlus®, ≥99.0%
Sigma-Aldrich
L -抗坏血酸, meets USP testing specifications
Sigma-Aldrich
硝酸, puriss. p.a., ≥65% (T)
Sigma-Aldrich
L -抗坏血酸, reagent grade
Supelco
硝酸溶液, 0.1 M HNO3 in water (0.1N), eluent concentrate for IC
Sigma-Aldrich
硝酸, ACS reagent, ≥90.0%
Sigma-Aldrich
L -抗坏血酸, puriss. p.a., ACS reagent, reag. ISO, Ph. Eur., 99.7-100.5% (oxidimetric)
Sigma-Aldrich
L -抗坏血酸, FCC, FG
Sigma-Aldrich
L -抗坏血酸, BioUltra, ≥99.5% (RT)
Sigma-Aldrich
L-丝氨酸, BioUltra, ≥99.5% (NT)
维生素C, European Pharmacopoeia (EP) Reference Standard
Sigma-Aldrich
L -抗坏血酸, puriss. p.a., ≥99.0% (RT)
Supelco
L-丝氨酸, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
L -抗坏血酸, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland