Merck
CN
  • Multidetector CT measurement of myocardial extracellular volume in acute patchy and contiguous infarction: validation with microscopic measurement.

Multidetector CT measurement of myocardial extracellular volume in acute patchy and contiguous infarction: validation with microscopic measurement.

Radiology (2014-09-24)
Robert Jablonowski, Mark W Wilson, Loi Do, Steven W Hetts, Maythem Saeed
摘要

To provide proof of concept that expansion of myocardial extracellular volume (MECV), measured at contrast material-enhanced multidetector computed tomography (CT), can be used as a (a) marker for viability based on histologic confirmation and (b) predictor of severity of myocardial injury. Animals cared for in compliance with Institutional Animal Care and Use Committee served as controls (group 1, n = 6) or were subjected to microinfarction by using 16-mm(3) (60 000 count) microemboli (group 2) and 32-mm(3) (120 000 count) microemboli (group 3), contiguous infarct with left anterior descending artery (LAD) occlusion followed by reperfusion (group 4), or the combination of LAD occlusion and 32-mm(3) microemboli followed by reperfusion (group 5) (n = 7 per group). MECV calculations were based on regional measurements of signal attenuation at contrast-enhanced multidetector CT and counterstaining of infarct at microscopy. Two-way analysis of variance and Student t tests were used to determine significant differences (P < .05). Data were presented as means ± standard deviations. Mean signal attenuation at equilibrium state of contrast media distribution (10 minutes) was significantly different among blood (137 HU ± 10), myocardial muscle (77 HU ± 12, P < .05), and skeletal muscle (35 HU ± 12, P < .05). Patchy microinfarct, contiguous infarct, and microinfarct with preexisting contiguous infarct can be differentiated on the basis of mean MECV (24% ± 3 [group 1] vs 36% ± 3 [group 2], P < .01, and 55% ± 5 [group 4], 56% ± 4 [group 5] vs 41% ± 3 [group 3], P < .05). Microscopy measurements confirmed multidetector CT quantitative measurements and differences in patterns of infarct caused by obstruction of major and minor coronary arteries. Regression analysis revealed excellent correlation between regional MECV using multidetector CT and microscopy (r(2) = 0.92). Contrast-enhanced multidetector CT is a suitable noninvasive imaging technique for assessing MECV in acute patchy and contiguous infarct caused by obstruction of major and minor coronary vessels.

材料
货号
品牌
产品描述

Sigma-Aldrich
碘海醇, nonionic density gradient medium
Supelco
利多卡因, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
甲氧苄啶, ≥98.5%
Supelco
甲氧苄啶, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
甲氧苄啶, ≥99.0% (HPLC)
USP
利多卡因, United States Pharmacopeia (USP) Reference Standard
Supelco
甲氧苄啶, VETRANAL®, analytical standard
利多卡因, European Pharmacopoeia (EP) Reference Standard
Supelco
卡洛芬, Pharmaceutical Secondary Standard; Certified Reference Material
USP
甲氧苄啶, United States Pharmacopeia (USP) Reference Standard
Supelco
碘海醇, analytical standard
Supelco
卡洛芬, VETRANAL®, analytical standard
甲氧苄啶, European Pharmacopoeia (EP) Reference Standard
甲氧苄啶, European Pharmacopoeia (EP) Reference Standard
碘海醇, European Pharmacopoeia (EP) Reference Standard
卡洛芬, European Pharmacopoeia (EP) Reference Standard
卡洛芬, European Pharmacopoeia (EP) Reference Standard
碘海醇, European Pharmacopoeia (EP) Reference Standard