  • Parallel dual secondary column-dual detection: a further way of enhancing the informative potential of two-dimensional comprehensive gas chromatography.

Parallel dual secondary column-dual detection: a further way of enhancing the informative potential of two-dimensional comprehensive gas chromatography.

Journal of chromatography. A (2014-08-19)
Luca Nicolotti, Chiara Cordero, Davide Bressanello, Cecilia Cagliero, Erica Liberto, Federico Magagna, Patrizia Rubiolo, Barbara Sgorbini, Carlo Bicchi
摘要

Comprehensive two-dimensional gas chromatography (GC×GC) coupled with Mass Spectrometry (MS) is one of today's most powerful analytical platforms for detailed analysis of medium-to-high complexity samples. The column set usually consists of a long, conventional-inner-diameter first dimension ((1)D) (typically 15-30m long, 0.32-0.25mm dc), and a short, narrow-bore second dimension ((2)D) column (typically 0.5-2m, 0.1mm dc) where separation is run in a few seconds. However, when thermal modulation is used, since the columns of a set are coupled in series, a flow mismatch occurs between the two dimensions, making it impossible to operate simultaneously at optimized flow conditions. Further, short narrow-bore capillaries can easily be overloaded, because of their lower loadability, limiting the effectiveness of (2)D separation. In this study, improved gas linear velocities in both chromatographic dimensions were achieved by coupling the (1)D column with two parallel (2)D columns, having identical inner diameter, stationary phase chemistry, and film thickness. In turn, these were connected to two detectors: a fast quadrupole Mass Spectrometer (MS) and a Flame Ionization Detector (FID). Different configurations were tested and performances compared to a conventional set-up; experimental results on two model mixtures (n-alkanes and fourteen medium-to-high polarity volatiles of interest in the flavor and fragrance field) and on the essential oil of Artemisia umbelliformis Lam., show the system provides consistent results, in terms of analyte identification (reliability of spectra and MS matching) and quantitation, also affording an internal cross-validation of quantitation accuracy.

材料
货号
品牌
产品描述

Supelco
苯甲醇, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
苯甲醛, ReagentPlus®, ≥99%
Sigma-Aldrich
香草醛, ReagentPlus®, 99%
Sigma-Aldrich
苯甲醇, anhydrous, 99.8%
Sigma-Aldrich
苯甲醇, ReagentPlus®, ≥99%
Sigma-Aldrich
苯甲醇, ACS reagent, ≥99.0%
Supelco
香草醛熔点标准品, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
苯甲醛, purified by redistillation, ≥99.5%
Supelco
苯甲醛, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
苯甲酸苄酯, ReagentPlus®, ≥99.0%
Sigma-Aldrich
香豆素, ≥99% (HPLC)
Sigma-Aldrich
樟脑, 96%
苯甲醛, European Pharmacopoeia (EP) Reference Standard
Sigma-Aldrich
肉桂醇, 98%
Supelco
苯甲醇, analytical standard
USP
苯甲醇, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
苯甲醛, puriss. p.a., ≥99.0% (GC)
Supelco
香草醛, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
苯甲醇, puriss. p.a., ACS reagent, ≥99.0% (GC)
Sigma-Aldrich
苯甲醇, puriss., meets analytical specification of Ph. Eur., BP, NF, 99-100.5% (GC)
Sigma-Aldrich
香草醛, natural, ≥97%, FCC, FG
Supelco
苯甲酸苄酯, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
香草醛, ≥97%, FCC, FG
Sigma-Aldrich
乙酸香叶酯, ≥97%
Sigma-Aldrich
异丁香酚, 98%, mixture of cis and trans
Sigma-Aldrich
苯甲酸苄酯, ≥99%, FCC, FG
Sigma-Aldrich
苯甲醛, natural, FCC, FG
Sigma-Aldrich
苯甲醇, ≥99%, FCC, FG
Supelco
苯甲醛, analytical standard
Supelco
乙酸香叶酯, analytical standard