跳转至内容
Merck
CN
  • Comparison of dexamethasone intravitreal implant and intravitreal triamcinolone acetonide for the treatment of pseudophakic cystoid macular edema in diabetic patients.

Comparison of dexamethasone intravitreal implant and intravitreal triamcinolone acetonide for the treatment of pseudophakic cystoid macular edema in diabetic patients.

Drug design, development and therapy (2014-09-27)
Yalong Dang, Yalin Mu, Lin Li, Yahui Mu, Shujing Liu, Chun Zhang, Yu Zhu, Yimin Xu
摘要

Our objective was to investigate the efficacy and safety of dexa methasone (DEX) implant for the treatment of pseudophakic cystoid macular edema (PCME) in diabetic patients. This was a prospective, non-randomized, interventional case series of 43 participants. Eighteen patients were enrolled in the DEX implant group and 25 were enrolled in an intravitreal triamcinolone acetonide (IVTA) group. The primary efficacy measurement was the percentage of patients who gained improvements of more than ten letters in best corrected visual acuity (BCVA) during 6 months of follow-up. Other efficacy measurements included change in BCVA, change in central macular thickness (CMT), and number of retreatments. The primary safety evaluation was the percentage of patients with intraocular hypertension and variation in intraocular pressure (IOP) during 6 months of follow-up. Other adverse events, such as conjunctival hemorrhage, eye pain, secondary infection, endophthalmitis, noninfectious inflammation, retinal detachment, and implant migration, were also recorded during follow-up. At month 1, we observed that the percentage of patients gaining improvement of more than ten letters was similar in both groups (P = 0.625). As patients in the IVTA group were retreated several times, this effect persisted throughout the study (P = 0.941 at month 2, P = 0.553 at month 3, P = 0.856 at month 6). Variations in CMT were noticed at week 1 and reached their maximum at month 1. No significant difference was found between the two groups (P = 0.831 at week 1, P = 0.783 at month 1). At month 1, the variation in IOP reached its maximum in the DEX implant group and then decreased slightly. However, in the IVTA group, it increased continuously throughout the study. Conjunctival hemorrhage and eye pain were found in both groups, but both were rated as mild in severity, and no significant difference was found (P = 0.184, P = 0.766, respectively). Both IVTA and DEX implants could effectively restore visual function and recover morphological change in diabetic patients with PCME for at least 6 months, but repeated intravitreal injection was required in the IVTA group. DEX implant is well tolerated. We suggest that intravitreal injection of DEX implant is a promising new therapeutic option for diabetic patients with PCME.

材料
产品编号
品牌
产品描述

Sigma-Aldrich
双氯芬酸钠 钠盐
Supelco
双氯芬酸钠 钠盐, Pharmaceutical Secondary Standard; Certified Reference Material
USP
双氯芬酸钠, United States Pharmacopeia (USP) Reference Standard
Supelco
双氯芬酸钠 钠盐, analytical standard
双氯芬酸钠, European Pharmacopoeia (EP) Reference Standard
双氯芬酸钠, European Pharmacopoeia (EP) Reference Standard
Sigma-Aldrich
托吡卡胺, solid
托吡卡胺, European Pharmacopoeia (EP) Reference Standard