Merck
CN
  • Large-Scale Interlaboratory Study to Develop, Analytically Validate and Apply Highly Multiplexed, Quantitative Peptide Assays to Measure Cancer-Relevant Proteins in Plasma.

Large-Scale Interlaboratory Study to Develop, Analytically Validate and Apply Highly Multiplexed, Quantitative Peptide Assays to Measure Cancer-Relevant Proteins in Plasma.

Molecular & cellular proteomics : MCP (2015-02-20)
Susan E Abbatiello, Birgit Schilling, D R Mani, Lisa J Zimmerman, Steven C Hall, Brendan MacLean, Matthew Albertolle, Simon Allen, Michael Burgess, Michael P Cusack, Mousumi Gosh, Victoria Hedrick, Jason M Held, H Dorota Inerowicz, Angela Jackson, Hasmik Keshishian, Christopher R Kinsinger, John Lyssand, Lee Makowski, Mehdi Mesri, Henry Rodriguez, Paul Rudnick, Pawel Sadowski, Nell Sedransk, Kent Shaddox, Stephen J Skates, Eric Kuhn, Derek Smith, Jeffery R Whiteaker, Corbin Whitwell, Shucha Zhang, Christoph H Borchers, Susan J Fisher, Bradford W Gibson, Daniel C Liebler, Michael J MacCoss, Thomas A Neubert, Amanda G Paulovich, Fred E Regnier, Paul Tempst, Steven A Carr
摘要

There is an increasing need in biology and clinical medicine to robustly and reliably measure tens to hundreds of peptides and proteins in clinical and biological samples with high sensitivity, specificity, reproducibility, and repeatability. Previously, we demonstrated that LC-MRM-MS with isotope dilution has suitable performance for quantitative measurements of small numbers of relatively abundant proteins in human plasma and that the resulting assays can be transferred across laboratories while maintaining high reproducibility and quantitative precision. Here, we significantly extend that earlier work, demonstrating that 11 laboratories using 14 LC-MS systems can develop, determine analytical figures of merit, and apply highly multiplexed MRM-MS assays targeting 125 peptides derived from 27 cancer-relevant proteins and seven control proteins to precisely and reproducibly measure the analytes in human plasma. To ensure consistent generation of high quality data, we incorporated a system suitability protocol (SSP) into our experimental design. The SSP enabled real-time monitoring of LC-MRM-MS performance during assay development and implementation, facilitating early detection and correction of chromatographic and instrumental problems. Low to subnanogram/ml sensitivity for proteins in plasma was achieved by one-step immunoaffinity depletion of 14 abundant plasma proteins prior to analysis. Median intra- and interlaboratory reproducibility was <20%, sufficient for most biological studies and candidate protein biomarker verification. Digestion recovery of peptides was assessed and quantitative accuracy improved using heavy-isotope-labeled versions of the proteins as internal standards. Using the highly multiplexed assay, participating laboratories were able to precisely and reproducibly determine the levels of a series of analytes in blinded samples used to simulate an interlaboratory clinical study of patient samples. Our study further establishes that LC-MRM-MS using stable isotope dilution, with appropriate attention to analytical validation and appropriate quality control measures, enables sensitive, specific, reproducible, and quantitative measurements of proteins and peptides in complex biological matrices such as plasma.

材料
货号
品牌
产品描述

Sigma-Aldrich
尿素, ACS reagent, 99.0-100.5%
Sigma-Aldrich
DL-二硫代苏糖醇 溶液, BioUltra, for molecular biology, ~1 M in H2O
Sigma-Aldrich
尿素, powder, BioReagent, for molecular biology, suitable for cell culture
Sigma-Aldrich
碘乙酰胺, Single use vial of 56 mg
Sigma-Aldrich
碘乙酰胺, BioUltra
Supelco
DL-二硫代苏糖醇 溶液, 1 M in H2O
Sigma-Aldrich
碘乙酰胺, ≥99% (NMR), crystalline
Sigma-Aldrich
尿素, ReagentPlus®, ≥99.5%, pellets
Supelco
尿素, 8 M (after reconstitution with 16 mL high purity water)
Sigma-Aldrich
尿素 溶液, BioUltra, ~8 M in H2O
Sigma-Aldrich
尿素, puriss., meets analytical specification of Ph. Eur., BP, USP, 99.0-100.5%, 99.0-101.0% (calc. on dry substance)
Sigma-Aldrich
尿素, BioXtra, pH 7.5-9.5 (20 °C, 5 M in H2O)
Sigma-Aldrich
尿素, puriss. p.a., ACS reagent, reag. Ph. Eur., ≥99%
Sigma-Aldrich
尿素, suitable for electrophoresis
Sigma-Aldrich
尿素, BioUltra, for molecular biology, 99% (T)
Sigma-Aldrich
尿素 溶液, 40 % (w/v) in H2O
Sigma-Aldrich
尿素, meets USP testing specifications
SAFC
碘乙酰胺
Sigma-Aldrich
尿素-12C, 99.9 atom % 12C
Sigma-Aldrich
尿素, Vetec, reagent grade, 99%
Sigma-Aldrich
碘乙酰胺, Vetec, reagent grade, 98%