跳转至内容
Merck
CN
  • Selective extraction and analysis of catecholamines in rat blood microdialysate by polymeric ionic liquid-diphenylboric acid-packed capillary column and fast separation in high-performance liquid chromatography-electrochemical detector.

Selective extraction and analysis of catecholamines in rat blood microdialysate by polymeric ionic liquid-diphenylboric acid-packed capillary column and fast separation in high-performance liquid chromatography-electrochemical detector.

Journal of chromatography. A (2015-07-25)
Xinguang Zhou, Anwei Zhu, Guoyue Shi
摘要

Concentration of blood catecholamines (CAs) is linked to a host of cardiovascular diseases, including hypertension and stenocardia. The matrix interferences and low concentration require tedious sample pretreatment methods before quantitative analysis by the gold standard method of high-performance liquid chromatography-electrochemical detector (HPLC-ECD). Solid phase extraction (SPE) has been widely used as the pretreatment technique. Here, a facile polymeric ionic liquid (PIL)-diphenylboric acid (DPBA)-packed capillary column was prepared to selectively extract dopamine (DA), noradrenaline (NE) and epinephrine (E) prior to their quantitative analysis by a fast separation in HPLC-ECD method, while microdialysis sampling method was applied to get the analysis sample. Parameters that influenced desorption efficiency, such as pH, salt concentration, acetonitrile content and wash time, were examined and optimized. The proposed method, combining microdialysis sampling technique, SPE and HPLC-ECD system, was successfully applied to detect CAs in rat blood microdialysate with high sensitivity and selectivity in small sample volumes (5-40μl) and a short analysis time (8min), yielding good reproducibility (RSD 6.5-7.7%) and spiked recovery (91-104.4%).

材料
Product Number
品牌
产品描述

Sigma-Aldrich
二甲基亚砜, Hybri-Max, sterile-filtered, BioReagent, suitable for hybridoma, ≥99.7%
Sigma-Aldrich
二甲基亚砜, Molecular Biology
Sigma-Aldrich
二甲基亚砜, sterile-filtered, BioPerformance Certified, meets EP, USP testing specifications, suitable for hybridoma
Sigma-Aldrich
二甲基亚砜, anhydrous, ≥99.9%
Sigma-Aldrich
2-丙醇, BioReagent, ≥99.5%, Molecular Biology
Sigma-Aldrich
二甲基亚砜, ≥99.5% (GC), suitable for plant cell culture
Sigma-Aldrich
甲醇, anhydrous, 99.8%
Sigma-Aldrich
2-丙醇, anhydrous, 99.5%
Sigma-Aldrich
二甲基亚砜, BioUltra, Molecular Biology, ≥99.5% (GC)
Sigma-Aldrich
异丙醇, ≥99.7%, FCC, FG
Sigma-Aldrich
二乙烯基苯, technical grade, 55%
Sigma-Aldrich
2-丙醇, BioUltra, Molecular Biology, ≥99.5% (GC)
Sigma-Aldrich
二甲基亚砜, meets EP testing specifications, meets USP testing specifications
Sigma-Aldrich
2-丙醇, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
二甲基亚砜, PCR Reagent
Sigma-Aldrich
高香草酸, Fluorimetric reagent
Sigma-Aldrich
DL-4-羟基-3-甲氧基扁桃酸, ≥98% (HPLC), powder
Sigma-Aldrich
甲醇, suitable for NMR (reference standard)
Sigma-Aldrich
1-氯-3-苯基丙烷, 99%
Sigma-Aldrich
甲醇 溶液, suitable for NMR (reference standard), 4% in methanol-d4 (99.8 atom % D), NMR tube size 3 mm × 8 in.
Sigma-Aldrich
8-Octanoyloxypyrene-1,3,6-trisulfonic acid trisodium salt, suitable for fluorescence, ≥90% (HPCE)
Sigma-Aldrich
二甲基亚砜, Vetec, reagent grade, 99%
Sigma-Aldrich
甲醇 溶液, contains 0.50 % (v/v) triethylamine
Sigma-Aldrich
甲醇, purification grade, 99.8%