跳转至内容
Merck
CN

GC Analysis of Pesticides in Spinach on SLB®-5ms after QuEChERS Extraction then SPE Clean-up using Supelclean ENVI-Carb/NH2 Dual Layer

GC Analysis of Pesticides in Spinach on SLB®-5ms after QuEChERS Extraction then SPE Clean-up using Supelclean™ ENVI-Carb/NH2 Dual Layer suitable for GC, application for SPE

材料

used together

产品编号
说明
价格

Visiprep SPE Vacuum Manifold, PTFE Free

standard, 12-port model

Disposable Liners for Visiprep DL Manifolds (included with 57044 and 57265)

PTFE, pk of 100

Supelclean ENVI-Carb/NH2 SPE Tube

bed A 500 mg (Supelclean ENVI-Carb), bed B 500 mg (Supelclean LC-NH2), volume 6 mL, pk of 30

相关产品

产品编号
说明
价格

Supel QuE

Acetate Tube, pk of 50, AOAC® 2007.01

CONDITIONS

sample preparation

Solid Phase Extraction (SPE)

sample/matrix

Spinach extract by QuEChERS, as described in the pretreatment step

SPE tube/cartridge

Supelclean ENVI-Carb/NH2 SPE Cartridge, 6 mL (54035-U)

extraction process

to 10 g homogenized spinach, add 10 mL acetonitrile, shake 1 min, add contents of Supel QuE acetate tube (55234-U), shake 1 min, centrifuge, transfer extract to dSPE tube, (add 1 g anhydrous MgSO4, shake 1 min and centrifuge, transfer 5 mL extract to glass tube, evaporate to 1 mL, add 250 μL toluene for a final volume of 1.25 mL QuEChERS extract)

condition

10 mL acetonitrile:toluene (75:25), discard

sample addition

1.25 mL spinach QuEChERS extract

elution

20 mL acetonitrile:toluene (75:25), gravity elution

eluate post-treatment

adjust volume of sample extract to 21.25 mL

column

SLB-5ms, 20 m x 0.18 mm I.D., 0.36 μm (28576-U)

oven

50 °C (0.5 min), 25 °C/min to 125 °C (0 min), 10 °C/min to 300 °C (5 min)

inj. temp.

60 °C (0.28 min), 600 °C/min to 325 °C (5 min)

detector

MSD

MSD interface

325 °C

scan range

SIM

carrier gas

helium

injection

10 μL, PTV solvent vent, purge flow to split vent 60 mL/min at 2.78 min, vent flow 100 mL/min

liner

4 mm I.D., split/splitless type, wool packed single taper FocusLiner design (2877505-U)

说明

分析说明

Pigments, sterols, sugars, organic acids and fatty acids when extracted from leafy greens such as spinach, pose problems for long term GC performance. An effective clean-up technique is required that will isolate/retain matrix interferences without effecting the pesticide analytes of interest. Solid Phase Extraction is a common and efficient approach to effectively clean up extracts and reduce interferences for low concentration residue analysis. A 6 mL Supelclean ENVI-Carb/ NH2 (54035-U) SPE tube is used for clean-up of spinach extract for GC/MS analysis and produces good recoveries with very low background.

Sample pretreatment: to 10 g homogenized spinach add 10 mL acetonitrile and shake 1 min, add contents of Supel QuE acetate tube (55234-U), shake 1 min and centrifuge, transfer extract to dSPE tube, add 1 g anhydrous MgSO4, shake 1 min and centrifuge, transfer 5 mL extract to glass tube, evaporate to 1 mL, add 250 μL toluene for a final volume of 1.25 mL QuEChERS extract

法律信息

SLB is a registered trademark of Merck KGaA, Darmstadt, Germany, Supelclean is a trademark of Sigma-Aldrich Co. LLC