  • [Preparation and applications of a supported liquid-liquid extraction column with a composite diatomite material].

[Preparation and applications of a supported liquid-liquid extraction column with a composite diatomite material].

Se pu = Chinese journal of chromatography (2012-12-22)
Jianmin Bao, Zhishuang Ma, Ying Sun, Yongzun Wang, Youxin Li
摘要

A rapid and special supported liquid-liquid extraction (SLE) column was developed with a composite diatomite material. The SLE column was evaluated by high performance liquid chromatography (HPLC) with acidic, neutral and alkaline compounds dissolved in water. Furthermore, some real complex samples were also analyzed by HPLC with the SLE method. The recoveries of benzoic acid (acidic), p-nitroaniline (alkaline) and 4-hydroxy-benzoic methyl ester (neutral) treated by the SLE column were 90.6%, 98.1% and 97.7%. However, the recoveries of the three compounds treated by traditional liquid-liquid extraction (LLE) method were 71.9%, 81.9% and 83.9%. The results showed that the SLE technique had higher recoveries than the traditional LLE method. The spiked recoveries of the complex samples, such as benzoic acid in Sprite and dexamethasone acetate, chlorphenamine maleate, indomethacin in bovine serum, were between 80% and 110% and the relative standard deviations (RSDs) were less than 15%. For biological specimen, the results could be accepted. Meantime, many disadvantages associated with traditional LLE method, such as emulsion formation, didn't occur using SLE column. The SLE column technique is a good sample preparation method with many advantages, such as rapid, simple, robust, easily automated, high recovery and high-throughput, which would be widely used in the future.

材料
产品编号
品牌
产品描述

Sigma-Aldrich
硅藻土 ®545, filter aid, treated with sodium carbonate, flux calcined
Sigma-Aldrich
苯甲酸, ACS reagent, ≥99.5%
Sigma-Aldrich
过滤剂, Celite® 545
Supelco
苯甲酸, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Celatom®,酸洗硅藻土, for use in Total Dietary Fiber Assay, TDF-100A
Sigma-Aldrich
Celite® S, filter aid, dried, untreated
Sigma-Aldrich
硅藻土®, filter aid, flux calcined, treated with sodium carbonate
Supelco
Mettler-Toledo 校准物质 ME 18555,苯甲酸, analytical standard, (for the calibration of the melting point system), traceable to primary standards (LGC)
Supelco
Melting point standard 121-123°C, analytical standard
Sigma-Aldrich
硅藻土
Sigma-Aldrich
苯甲酸, meets analytical specification of Ph. Eur., BP, USP, FCC, E210, 99.5-100.5% (alkalimetric)
Sigma-Aldrich
Celite® 545 AW, filter aid, acid washed, treated with sodium carbonate, flux calcined
Supelco
Celite® 545 AW, reagent grade
Sigma-Aldrich
未洗涤的硅藻土, powder
Supelco
苯甲酸, reference material for titrimetry, certified by BAM, >99.5%
Sigma-Aldrich
硅藻土, meets USP/NF testing specifications
Sigma-Aldrich
Celite® 535, filter aid, flux calcined
Sigma-Aldrich
苯甲酸, ≥99.5%, FCC, FG
Sigma-Aldrich
硅藻土, filter aid, treated with sodium carbonate, calcined
Sigma-Aldrich
苯甲酸, ReagentPlus®, 99%
Sigma-Aldrich
苯甲酸, puriss. p.a., ACS reagent, reag. Ph. Eur., ≥99.9% (alkalimetric)
Supelco
苯甲酸, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Sigma-Aldrich
苯甲酸, natural, ≥99.5%, FCC, FG
Sigma-Aldrich
苯甲酸钾, ReagentPlus®, 99%
Sigma-Aldrich
苯甲酸, purified by sublimation, ≥99%
醋酸地塞米松, European Pharmacopoeia (EP) Reference Standard