跳转至内容
Merck
CN
  • Simultaneous determination of propofol and its glucuronide in whole blood by liquid chromatography-electrospray tandem mass spectrometry and the influence of sample storage conditions on the reliability of the test results.

Simultaneous determination of propofol and its glucuronide in whole blood by liquid chromatography-electrospray tandem mass spectrometry and the influence of sample storage conditions on the reliability of the test results.

Journal of pharmaceutical and biomedical analysis (2015-03-17)
Lambert K Sørensen, Jørgen B Hasselstrøm
摘要

Propofol (2,6-diisopropylphenol) is commonly used as an anaesthetic agent but is also abused for recreational purposes. Several cases of fatalities involving self-administered propofol have been reported. For rapid quantification of propofol and propofol β-d-glucuronide (propofol G) in clinical and forensic cases, an ultra-performance liquid chromatography-tandem mass spectrometry method using pneumatically assisted electrospray ionisation has been developed. The technique has been validated on both ante-mortem and post-mortem human whole blood. The proteins in the blood samples were removed by the addition of a mixture of methanol and acetonitrile, and the extract was cleaned up by solid phase extraction. The extract was concentrated in dimethyl sulphoxide. The system was calibrated using matrix-matched calibrants combined with isotope dilution. The lower limits of quantification were 0.01 and 0.02mg/L for propofol and 0.02 and 0.04mg/L for propofol G in ante-mortem and post-mortem whole blood, respectively. The relative intra-laboratory reproducibility standard deviation was less than 10% at concentrations of 0.2mg/L or higher. The mean true extraction recovery was 85% for propofol and 81% for propofol G. The trueness of the propofol determination expressed as the relative bias of the test results was within ±6% at concentration levels of 0.01-8.5mg/L. Propofol was less stable in blood stabilised with a citrate-EDTA-fluoride mixture than in blood stabilised with an oxalate-fluoride mixture. The stability was lower at -20°C than at 5°C and -80°C. Propofol G did not show instability under the storage conditions tested.

材料
产品编号
品牌
产品描述

Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
甲醇, suitable for HPLC, ≥99.9%
Sigma-Aldrich
二甲基亚砜, Hybri-Max, sterile-filtered, BioReagent, suitable for hybridoma, ≥99.7%
Sigma-Aldrich
二甲基亚砜, ACS reagent, ≥99.9%
Sigma-Aldrich
甲醇, ACS reagent, ≥99.8%
Sigma-Aldrich
二甲基亚砜, Molecular Biology
Sigma-Aldrich
二甲基亚砜, suitable for HPLC, ≥99.7%
Sigma-Aldrich
乙酸, glacial, ACS reagent, ≥99.7%
Sigma-Aldrich
甲醇, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
二甲基亚砜, sterile-filtered, BioPerformance Certified, meets EP, USP testing specifications, suitable for hybridoma
Sigma-Aldrich
乙酸, glacial, ReagentPlus®, ≥99%
Sigma-Aldrich
二甲基亚砜, ReagentPlus®, ≥99.5%
Sigma-Aldrich
二甲基亚砜, anhydrous, ≥99.9%
Sigma-Aldrich
甲醇, HPLC Plus, ≥99.9%
Sigma-Aldrich
乙腈, ACS reagent, ≥99.5%
Sigma-Aldrich
乙腈, anhydrous, 99.8%
Sigma-Aldrich
二甲基亚砜, ≥99.5% (GC), suitable for plant cell culture
Sigma-Aldrich
甲醇, anhydrous, 99.8%
Sigma-Aldrich
二甲基亚砜, puriss. p.a., ACS reagent, ≥99.9% (GC)
Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
乙酸, glacial, ≥99.99% trace metals basis
Sigma-Aldrich
乙腈, ≥99.9% (GC)
Sigma-Aldrich
乙酸, glacial, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8%
Sigma-Aldrich
乙酸 溶液, suitable for HPLC
Sigma-Aldrich
乙酸, glacial, puriss., meets analytical specification of Ph. Eur., BP, USP, 99.8-100.5%
Sigma-Aldrich
甲醇, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
甲醇, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
甲醇, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
甲醇, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
二甲基亚砜, BioUltra, Molecular Biology, ≥99.5% (GC)