跳转至内容
Merck
CN
  • Use of a carboxylesterase inhibitor of phenylmethanesulfonyl fluoride to stabilize epothilone D in rat plasma for a validated UHPLC-MS/MS assay.

Use of a carboxylesterase inhibitor of phenylmethanesulfonyl fluoride to stabilize epothilone D in rat plasma for a validated UHPLC-MS/MS assay.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2014-08-26)
Long Yuan, Yunlin Fu, Duxi Zhang, Yuan-Qing Xia, Qianping Peng, Anne-Françoise Aubry, Mark E Arnold
摘要

A sensitive, accurate and rugged UHPLC-MS/MS method was developed and validated for the quantitation of Epothilone D (EpoD), a microtubule stabilizer in development for treatment of Alzeimer's disease, in rat plasma. The ester group in EpoD can be hydrolyzed by esterases in blood or plasma, which creates a stability concern for the bioanalysis of EpoD. Species differences in the stability of EpoD in plasma were observed. Carboxylesterases were identified as the likely esterases responsible for the hydrolysis of EpoD in plasma ex vivo, and the cause of the species different stability. Phenylmethanesulfonyl fluoride, a carboxylesterase inhibitor, was used to stabilize EpoD in rat blood during sample collection, processing, and storage. A systematic method screening and optimization strategy was used to improve the assay sensitivity and minimize potential bioanalytical risks. The stabilized plasma samples were extracted by liquid-liquid extraction. Chromatographic separation was achieved on an Acquity UPLC BEH Phenyl column with a gradient elution. EpoD and its stable isotope labeled internal standards were detected by positive ion electrospray tandem mass spectrometry. The standard curve, which ranged from 0.100 to 100ng/mL was fitted to a 1/x(2) weighted linear regression model. The intra-assay precision was within ±3.6% CV and inter-assay precision was within ±4.2% CV. The assay accuracy was within ±8.3% of the nominal values. Assay recovery of EpoD was high (∼90%) and matrix effect was minimal (1.02-1.05). EpoD was stable in stabilized rat plasma for at least 30h at room temperature, 180 days at -20°C, and following three freeze-thaw cycles. The validated method was successfully applied to sample analysis in toxicology studies.

材料
产品编号
品牌
产品描述

Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
乙醇,Pure 200纯度, Molecular Biology
Sigma-Aldrich
纯乙醇, 200 proof, ACS reagent, ≥99.5%
Sigma-Aldrich
纯乙醇, 200 proof
Sigma-Aldrich
纯乙醇, 200 proof, meets USP testing specifications
Sigma-Aldrich
乙腈, ACS reagent, ≥99.5%
Sigma-Aldrich
乙腈, anhydrous, 99.8%
Sigma-Aldrich
纯乙醇, 200 proof, anhydrous, ≥99.5%
Supelco
甲酸铵, eluent additive for LC-MS, LiChropur, ≥99.0%
Sigma-Aldrich
1-氯丁烷, suitable for HPLC, ≥99.8%
Sigma-Aldrich
甲酸铵, reagent grade, 97%
Sigma-Aldrich
乙醇,Pure 190纯度, for molecular biology
Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
乙腈, ≥99.9% (GC)
Sigma-Aldrich
苯甲磺酰氟, ≥98.5% (GC)
Sigma-Aldrich
纯乙醇, 190 proof, ACS spectrophotometric grade, 95.0%
Sigma-Aldrich
甲酸铵, ≥99.995% trace metals basis
Sigma-Aldrich
酒精, BioUltra, Molecular Biology, ≥99.8%, (absolute alcohol, without additive, A15 o1)
Sigma-Aldrich
甲酸铵 溶液, BioUltra, 10 M in H2O
Sigma-Aldrich
乙腈, suitable for HPLC-GC, ≥99.8% (GC)
Sigma-Aldrich
苯甲磺酰氟, ≥99.0% (T)
Supelco
无水乙醇, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
纯乙醇, 190 proof, meets USP testing specifications
Supelco
酒精, standard for GC
Sigma-Aldrich
甲酸铵, BioUltra, ≥99.0% (calc. based on dry substance, NT)
Sigma-Aldrich
1-氯丁烷, ReagentPlus®, 99%
Sigma-Aldrich
乙腈, biotech. grade, ≥99.93%
Sigma-Aldrich
乙腈, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
甲酸, ≥95%, FCC, FG
Sigma-Aldrich
乙腈, suitable for DNA synthesis, ≥99.9% (GC)