跳转至内容
Merck
CN

Prevalence of heroin markers in urine for pain management patients.

Forensic science international (2014-05-27)
Julie Knight, Brandi L Puet, Anne DePriest, Rebecca Heltsley, Cheryl Hild, David L Black, Timothy Robert, Yale H Caplan, Edward J Cone
摘要

Surveys of current trends indicate heroin abuse is associated with nonmedical use of pain relievers. Consequently, there is an interest in evaluating the presence of heroin-specific markers in chronic pain patients who are prescribed controlled substances. A total of 926,084 urine specimens from chronic pain patients were tested for heroin/diacetylmorphine (DAM), 6-acetylmorphine (6AM), 6-acetylcodeine (6AC), codeine (COD), and morphine (MOR). Heroin and markers were analyzed using liquid chromatography tandem mass spectrometry (LC-MS-MS). Opiates were analyzed following hydrolysis using LC-MS-MS. The prevalence of heroin use was 0.31%, as 2871 were positive for one or more heroin-specific markers including DAM, 6AM, or 6AC (a known contaminant of illicit heroin). Of these, 1884 were additionally tested for the following markers of illicit drug use: 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA), methamphetamine (MAMP), 11-nor-9-carboxy-Δ(9)-tetracannabinol (THCCOOH), and benzoylecgonine (BZE); 654 (34.7%) had positive findings for one or more of these analytes. The overall prevalence of heroin markers were as follows: DAM 1203 (41.9%), 6AM 2570 (89.5%), 6AC 1082 (37.7%). MOR was present in 2194 (76.4%) and absent (<LOQ) in 677 (23.6%) of the heroin-positive specimens. COD was present in 1218 (42.4%) specimens. Prevalence of combinations for specimens containing MOR were as follows: DAM only 13 (0.59%), 6AM only 1140 (52.0%), 6AC only 24 (1.1%), DAM/6AM/6AC 710 (32.4%), 6AM/6AC 188 (8.6%), DAM/6AM 113 (5.2%), DAM/6AC 6 (0.27%). Importantly, the prevalence of combinations for specimens without MOR were as follows: DAM only 161 (23.8%), 6AM only 217 (32.1%), 6AC only 92 (13.6%), DAM/6AM/6AC 50 (7.4%), 6AM/6AC 7 (1.0%), DAM/6AM 145 (21.4%), DAM/6AC 5 (0.74%). Unexpected patterns of excretion were observed, such as the presence of DAM and 6AC in the absence of 6AM and MOR; therefore, multiple heroin markers may be useful to assess for heroin use.

材料
产品编号
品牌
产品描述

Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
甲醇, suitable for HPLC, ≥99.9%
Sigma-Aldrich
2-丙醇, suitable for HPLC, 99.9%
Sigma-Aldrich
2-丙醇, ACS reagent, ≥99.5%
Sigma-Aldrich
甲醇, ACS reagent, ≥99.8%
Sigma-Aldrich
二氯甲烷, suitable for HPLC, ≥99.8%, contains amylene as stabilizer
Sigma-Aldrich
甲醇, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
二氯甲烷, contains 40-150 ppm amylene as stabilizer, ACS reagent, ≥99.5%
Sigma-Aldrich
二氯甲烷, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%, contains 50-150 ppm amylene as stabilizer
Sigma-Aldrich
甲醇, HPLC Plus, ≥99.9%
Sigma-Aldrich
乙腈, ACS reagent, ≥99.5%
Sigma-Aldrich
二氯甲烷, anhydrous, ≥99.8%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
2-丙醇, BioReagent, ≥99.5%, Molecular Biology
Sigma-Aldrich
乙腈, anhydrous, 99.8%
Sigma-Aldrich
异丙醇, meets USP testing specifications
Sigma-Aldrich
2-丙醇, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%
Sigma-Aldrich
甲醇, anhydrous, 99.8%
Sigma-Aldrich
2-丙醇, anhydrous, 99.5%
Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
乙腈, ≥99.9% (GC)
Sigma-Aldrich
2-丙醇, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
甲醇, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
甲醇, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
甲醇, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
2-丙醇, Laboratory Reagent, ≥99.5%
Sigma-Aldrich
二氯甲烷, puriss. p.a., ACS reagent, reag. ISO, ≥99.9% (GC)
Sigma-Aldrich
二氯甲烷, ACS reagent, ≥99.5%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
甲醇, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
甲醇, ACS reagent, ≥99.8%
Sigma-Aldrich
异丙醇, ≥99.7%, FCC, FG