跳转至内容
Merck
CN
  • Multi-drug and metabolite quantification in postmortem blood by liquid chromatography-high-resolution mass spectrometry: comparison with nominal mass technology.

Multi-drug and metabolite quantification in postmortem blood by liquid chromatography-high-resolution mass spectrometry: comparison with nominal mass technology.

Journal of analytical toxicology (2014-09-14)
Thomas G Rosano, Seo Na, Kenneth Ihenetu, Thomas A Swift, Michelle Wood
摘要

High-resolution mass spectrometry (HRMS) is being applied in postmortem drug screening as an alternative to nominal mass spectrometry, and additional evaluation in quantitative casework is needed. We report quantitative analysis of benzoylecgonine, citalopram, cocaethylene, cocaine, codeine, dextromethorphan, dihydrocodeine, diphenhydramine, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine, hydrocodone, hydromorphone, meperidine, methadone, morphine, oxycodone and oxymorphone in postmortem blood by ultra-performance liquid chromatography (UPLC)-MS(E)/time-of-flight (TOF). The method employs analyte-matched deuterated internal standardization and MS(E) acquisition of precursor and product ions at low (6 eV) and ramped (10-40 eV) collision energies, respectively. Quantification was performed using precursor ion data obtained with a mass extraction window of ± 5 ppm. Fragment and residual precursor ion acquisitions at ramped collision energies were evaluated as additional analyte identifiers. Extraction recovery of >60% and matrix effect of <20% were determined for all analytes and internal standards. Defined limits of detection (10 ng/mL) and quantification (25 ng/mL) were validated along with a linearity analytical range of 25-3,000 ng/mL (R(2) > 0.99) for all analytes. Parallel UPLC-MS(E)/TOF and UPLC-MS/MS analysis showed comparable precision and bias along with concordance of 253 positive (y = 1.002x + 1.523; R(2) = 0.993) and 2,269 negative analyte findings in 159 postmortem cases. Analytical performance and correlation studies demonstrate accurate quantification by UPLC-MS(E)/TOF and extended application of HRMS in postmortem casework.

材料
产品编号
品牌
产品描述

Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
二氯甲烷, suitable for HPLC, ≥99.8%, contains amylene as stabilizer
Sigma-Aldrich
氢氧化铵 溶液, ACS reagent, 28.0-30.0% NH3 basis
Sigma-Aldrich
乙酸, glacial, ACS reagent, ≥99.7%
Sigma-Aldrich
二氯甲烷, contains 40-150 ppm amylene as stabilizer, ACS reagent, ≥99.5%
Sigma-Aldrich
乙酸, glacial, ReagentPlus®, ≥99%
Sigma-Aldrich
二氯甲烷, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%, contains 50-150 ppm amylene as stabilizer
Sigma-Aldrich
乙腈, ACS reagent, ≥99.5%
Sigma-Aldrich
二氯甲烷, anhydrous, ≥99.8%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
乙腈, anhydrous, 99.8%
Sigma-Aldrich
氢氧化铵 溶液, 28% NH3 in H2O, ≥99.99% trace metals basis
Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
乙酸, glacial, ≥99.99% trace metals basis
Sigma-Aldrich
乙腈, ≥99.9% (GC)
Sigma-Aldrich
乙酸, glacial, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8%
Sigma-Aldrich
乙酸 溶液, suitable for HPLC
Sigma-Aldrich
乙酸, glacial, puriss., meets analytical specification of Ph. Eur., BP, USP, 99.8-100.5%
Sigma-Aldrich
二氯甲烷, puriss. p.a., ACS reagent, reag. ISO, ≥99.9% (GC)
Sigma-Aldrich
氢氧化铵 溶液, puriss., 30-33% NH3 in H2O
Sigma-Aldrich
二氯甲烷, ACS reagent, ≥99.5%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
乙腈, suitable for HPLC-GC, ≥99.8% (GC)
Sigma-Aldrich
氢氧化铵 溶液, puriss. p.a., reag. ISO, reag. Ph. Eur., ~25% NH3 basis
Sigma-Aldrich
二氯甲烷, puriss., meets analytical specification of Ph. Eur., NF, ≥99% (GC)
Supelco
二氯甲烷, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
乙酸, suitable for luminescence, BioUltra, ≥99.5% (GC)
USP
冰醋酸, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
氢氧化铵 溶液, BioUltra, ~1 M NH3 in H2O (T)
Sigma-Aldrich
乙腈, biotech. grade, ≥99.93%
Sigma-Aldrich
乙腈, electronic grade, 99.999% trace metals basis
Supelco
二氯甲烷, analytical standard