跳转至内容
Merck
CN
  • Rapid extraction and determination of amphetamines in human urine samples using dispersive liquid-liquid microextraction and solidification of floating organic drop followed by high performance liquid chromatography.

Rapid extraction and determination of amphetamines in human urine samples using dispersive liquid-liquid microextraction and solidification of floating organic drop followed by high performance liquid chromatography.

Journal of pharmaceutical and biomedical analysis (2014-03-04)
Toraj Ahmadi-Jouibari, Nazir Fattahi, Mojtaba Shamsipur
摘要

A novel, rapid, simple and sensitive dispersive liquid-liquid microextraction method based on the solidification of floating organic drop (DLLME-SFO) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was used to determine amphetamine and methamphetamine in urine samples. The factors affecting the extraction efficiency of DLLME-SFO such as the kind and volume of the extraction and the disperser solvents, effect of concentration of K2CO3 and extraction time were investigated and the optimal extraction conditions were established. Under the optimum conditions (extraction solvent: 30.0μl 1-undecanol; disperser solvent: 300μl acetonitrile; buffer concentration: 2% (w/v) K2CO3 and extraction time: 1min), calibration curves are linear in the range of 10-3000μgl(-1) and limit of detections (LODs) are in the range of 2-8μgl(-1). The relative standard deviations (RSDs) for 100μgl(-1) of amphetamine and methamphetamine in diluted urine are in the range of 6.2-7.8% (n=7). The method was successfully applied for the determination of amphetamine and methamphetamine in the actual urine samples. The relative recoveries of urine samples spiked with amphetamine and methamphetamine are 87.8-113.2%. The obtained results show that DLLME-SFO combined with HPLC-UV is a fast and simple method for the determination of amphetamine and methamphetamine in urine.

材料
产品编号
品牌
产品描述

Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
乙腈, ACS reagent, ≥99.5%
Sigma-Aldrich
乙腈, anhydrous, 99.8%
Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
乙腈, ≥99.9% (GC)
Sigma-Aldrich
十六烷, ReagentPlus®, 99%
Sigma-Aldrich
乙腈, suitable for HPLC-GC, ≥99.8% (GC)
Sigma-Aldrich
十六烷, anhydrous, ≥99%
Sigma-Aldrich
1-癸醇, 98%
Sigma-Aldrich
乙腈, biotech. grade, ≥99.93%
Sigma-Aldrich
乙腈, electronic grade, 99.999% trace metals basis
Supelco
十六烷, analytical standard
Sigma-Aldrich
乙腈, suitable for DNA synthesis, ≥99.9% (GC)
Sigma-Aldrich
1-癸醇, ≥98%
Supelco
乙腈(纯品), Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
乙腈, analytical standard
Supelco
1-癸醇, analytical standard
Sigma-Aldrich
十一醇, 97%
Sigma-Aldrich
乙腈, ReagentPlus®, 99%
Sigma-Aldrich
1-癸醇, ≥98%, FCC, FG
Sigma-Aldrich
乙腈, ≥99.5% (GC)
Sigma-Aldrich
2-十二烷醇, 99%
USP
二类残留溶剂 - 甲醇, United States Pharmacopeia (USP) Reference Standard
Supelco
残留溶剂标准品-乙腈(DMSO溶液), Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
十一醇, 97%, FG
Sigma-Aldrich
十六烷, Vetec, reagent grade, 98%
Sigma-Aldrich
乙腈, Preparateur, ≥99.9% (GC), One-time steel-plastic (SP) drum