跳转至内容
Merck
CN
  • Electrochemiluminescence Resonance Energy Transfer System: Mechanism and Application in Ratiometric Aptasensor for Lead Ion.

Electrochemiluminescence Resonance Energy Transfer System: Mechanism and Application in Ratiometric Aptasensor for Lead Ion.

Analytical chemistry (2015-07-15)
Yan-Mei Lei, Wei-Xing Huang, Min Zhao, Ya-Qin Chai, Ruo Yuan, Ying Zhuo
摘要

In this paper, a novel electrochemiluminescence resonance energy transfer (ECL-RET) system from O2/S2O8(2-) to a kind of amino-terminated perylene derivative (PTC-NH2) was demonstrated for the first time, which was then applied to construct a ratiometric aptasensor for lead ion (Pb(2+)) detection. First, gold-nanoparticles-functionalized fullerene nanocomposites (AuNPs@nano-C60) were coated on a glassy carbon electrode (GCE), and then thiol-modified assistant probes (APs) were attached on AuNPs@nano-C60/GCE. Then the resultant electrode was hybridized with capture probes (the aptamer of the Pb(2+), abbreviated as CPs) to generate DNA duplexes, which could induce PTC-NH2 to be intercalated into the dsDNA grooves by the electrostatic adsorption. Herein, ECL dual peaks at -0.7 V (vs Ag/AgCl) and -2.0 V (vs Ag/AgCl) were obtained when the prepared aptasensor was detected in air-saturated S2O8(2-) solution, which could be attributed to the emission of excited dimmers (π-excimers) ((1)(NH2-PTC)2*) and (1)(O2)2*, respectively. In the presence of Pb(2+), the dsDNA was unwound, and Pb(2+) G-quadruplex structure was generated because of the highly specific affinity between Pb(2+) and CPs, which made the PTC-NH2 release from the electrode surface. As a result, the ECL signal at -0.7 V was decreased, and the ECL signal around -2.0 V was increased. By measuring the ratio of ECL intensities at two excitation potentials, the developed aptasensor exhibited the linear response range from 1.0 × 10(-12) M to 1.0 × 10(-7) M with a detection limit of 3.5 × 10(-13) M (S/N = 3) for Pb(2+), which could offer an alternative analytical method with excellent properties of high selectivity, accuracy, and sensitivity.

材料
产品编号
品牌
产品描述

Sigma-Aldrich
L -抗坏血酸, powder, suitable for cell culture, γ-irradiated
Sigma-Aldrich
L -抗坏血酸, BioXtra, ≥99.0%, crystalline
Sigma-Aldrich
L -抗坏血酸, suitable for cell culture, suitable for plant cell culture, ≥98%
Sigma-Aldrich
L -抗坏血酸, 99%
Sigma-Aldrich
L -抗坏血酸, reagent grade, crystalline
Sigma-Aldrich
乙二胺, ReagentPlus®, ≥99%
Sigma-Aldrich
L -抗坏血酸, ACS reagent, ≥99%
Sigma-Aldrich
L -抗坏血酸, meets USP testing specifications
Sigma-Aldrich
L -抗坏血酸, reagent grade
Sigma-Aldrich
乙二胺, purified by redistillation, ≥99.5%
Sigma-Aldrich
1-己硫醇, 95%
Sigma-Aldrich
L -抗坏血酸, puriss. p.a., ACS reagent, reag. ISO, Ph. Eur., 99.7-100.5% (oxidimetric)
Sigma-Aldrich
L -抗坏血酸, FCC, FG
Sigma-Aldrich
L -抗坏血酸, BioUltra, ≥99.5% (RT)
Sigma-Aldrich
L -抗坏血酸, puriss. p.a., ≥99.0% (RT)
Sigma-Aldrich
乙二胺, BioXtra
Sigma-Aldrich
乙二胺 二盐酸盐 溶液, technical, 75-80%
Sigma-Aldrich
1-己硫醇, 99% (GC)
Sigma-Aldrich
乙二胺, meets USP testing specifications
Sigma-Aldrich
L -抗坏血酸, Vetec, reagent grade, 99%