  • Quantitative fingerprinting of O-linked glycans released from proteins using isotopic coded labeling with deuterated 1-phenyl-3-methyl-5-pyrazolone.

Quantitative fingerprinting of O-linked glycans released from proteins using isotopic coded labeling with deuterated 1-phenyl-3-methyl-5-pyrazolone.

Journal of chromatography. A (2015-07-18)
Siniša Sić, Norbert M Maier, Andreas M Rizzi
摘要

Investigation of oligosaccharides attached to proteins as post-translational modification remains an important research field in the area of glycoproteomics as well as in biotechnology. The development of new tools for qualitative and quantitative analysis of glycans has gained high importance in recent years. This is particularly true with O-glycans for which quantitative data are still underrepresented in literature. This fact is probably due to the absence of an enzyme for general release of O-linked saccharides from glycoproteins and due to their low ionization yield in mass spectrometry (MS). In this paper, a method is established aimed at improved qualitative and quantitative analysis of mucin-type O-glycans. A chemical reaction combining release and derivatization of O-glycans in one step is combined here with mass spectrometric quantification. For the purpose of improved quantitative analysis, stable-isotope coded labeling by d0/d5 1-phenyl-3-methyl-5-pyrazolidone (PMP) was performed. The "heavy"-version of this label, penta-deutero (d5)-PMP, was synthesized for this purpose. Beneath improving the reproducibility of quantitation, PMP derivatization contributed to an enhancement of ionization yields in MS. By introducing an internal standard (e.g. GlcNAc3) the reproducibility for quantification can be improved. For higher abundant O-glycans a mean coefficient of variation (CV) less than 6% could be attained, for very low abundant CV values between 15 and 20%. For the determination of O-glycan profiles in mixtures, a HPLC separation was combined with a high resolution Qq-oaTOF instrument. RP-type stationary phases were successful in separating glycan species including some of isomeric ones. This separation step was particularly useful for removing of salts avoiding so the presence of various sodium clusters in the MS spectrum.

材料
Product Number
品牌
产品描述

Sigma-Aldrich
二氯甲烷, anhydrous, ≥99.8%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
乙腈, anhydrous, 99.8%
Sigma-Aldrich
甲醇, anhydrous, 99.8%
Sigma-Aldrich
盐酸 溶液, 1.0 N, BioReagent, suitable for cell culture
Sigma-Aldrich
D -(+)-半乳糖, ≥99% (HPLC), BioReagent, suitable for cell culture, suitable for insect cell culture
Sigma-Aldrich
盐酸, 36.5-38.0%, BioReagent, Molecular Biology
Sigma-Aldrich
乙酸乙酯, anhydrous, 99.8%
Supelco
盐酸 溶液, volumetric, 0.1 M HCl (0.1N), endotoxin free
Sigma-Aldrich
D -(+)-半乳糖, ≥99% (HPLC)
Sigma-Aldrich
氯仿, anhydrous, ≥99%, contains 0.5-1.0% ethanol as stabilizer
Sigma-Aldrich
亚硝酸钠, 99.999% trace metals basis
Sigma-Aldrich
氯仿, anhydrous, contains amylenes as stabilizer, ≥99%
Sigma-Aldrich
D-(+)-甘露糖, powder, BioReagent, suitable for cell culture
Sigma-Aldrich
盐酸 溶液, for amino acid analysis, ~6 M in H2O
Sigma-Aldrich
乙酸, suitable for luminescence, BioUltra, ≥99.5% (GC)
Sigma-Aldrich
乙酰乙酸乙酯, ReagentPlus®, 99%
Sigma-Aldrich
乙腈, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
盐酸 溶液, 32 wt. % in H2O, FCC
Sigma-Aldrich
D-(+)-甘露糖, ≥99% (GC), wood
Sigma-Aldrich
甲酸, ≥95%, FCC, FG
Sigma-Aldrich
乙酸, ≥99.5%, FCC, FG
Sigma-Aldrich
乙酸, natural, ≥99.5%, FG
Sigma-Aldrich
乙酸乙酯, ≥99%, FCC, FG
Sigma-Aldrich
氯化锡(II), anhydrous, powder, ≥99.99% trace metals basis
Sigma-Aldrich
二氯甲烷, suitable for HPLC, ≥99.9%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
氯化锡(II), ≥99.99% trace metals basis
Sigma-Aldrich
乙酰乙酸乙酯, natural, ≥97%, FG
Sigma-Aldrich
氯仿, ≥99%, PCR Reagent, contains amylenes as stabilizer
Sigma-Aldrich
乙酸乙酯, natural, ≥99%, FCC, FG
Sigma-Aldrich
D -(+)-半乳糖, BioXtra, ≥99% (HPLC)