跳转至内容
Merck
CN
  • Dissolution of biological samples in deep eutectic solvents: an approach for extraction of polycyclic aromatic hydrocarbons followed by liquid chromatography-fluorescence detection.

Dissolution of biological samples in deep eutectic solvents: an approach for extraction of polycyclic aromatic hydrocarbons followed by liquid chromatography-fluorescence detection.

Journal of chromatography. A (2015-04-11)
Zahra Helalat-Nezhad, Kamal Ghanemi, Mehdi Fallah-Mehrjardi
摘要

A novel sample preparation method based on the complete dissolution of marine biological samples in choline chloride-oxalic acid (ChCl-Ox) deep eutectic solvent was developed for fast and efficient extraction of eight polycyclic aromatic hydrocarbons (PAHs) using minimum volumes of cyclohexane. The extracted PAHs were purified and then measured by high-performance liquid chromatography-fluorescence detection (HPLC-FL). The effect of key parameters on extraction recoveries and precision was investigated. At optimized conditions, the studied samples were dissolved under atmospheric pressure in ChCl-Ox (1:2) at 55°C for 30min, which is considerably lower than the temperature used in the classical and current methods. After dissolution, it took approximately 20min to quantitatively extract the PAHs from ChCl-Ox using 5mL cyclohexane. Depending on the analyte, the developed method was linear over the calibration range 1.0-250, 2.0-250, and 5.0-250ngg(-1), with r(2)>0.996. The detection limits of the method were between 0.50 and 3.08ngg(-1). The intra-day and inter-day precisions (based on the relative standard deviation, n=5) of the spiked PAHs at a concentration level of 50ngg(-1) were better than 12.6% and 13.3%, respectively. Individual PAH recoveries from spiked marine fish and macroalgae samples were in the range of 71.6% to 109.6%. For comparison, the spiked samples were also subjected to the Soxhlet extraction method. The simplicity of the procedure, high extraction efficiency, short analysis time, and use of safe and inexpensive components suggest the proposed method has a high potential for utilization in routine trace PAH analysis in biological samples.

材料
产品编号
品牌
产品描述

Sigma-Aldrich
二氯甲烷, anhydrous, ≥99.8%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
乙腈, anhydrous, 99.8%
Sigma-Aldrich
甲苯, anhydrous, 99.8%
Sigma-Aldrich
氯化胆碱, ≥98%
Sigma-Aldrich
草酸, 98%
Sigma-Aldrich
正己烷, anhydrous, 95%
Sigma-Aldrich
氯化胆碱, BioReagent, suitable for cell culture, suitable for insect cell culture, ≥98%
Sigma-Aldrich
草酸, ReagentPlus®, ≥99%
Sigma-Aldrich
氯化胆碱, ≥99%
Sigma-Aldrich
草酸, purified grade, 99.999% trace metals basis
Sigma-Aldrich
环己烷, anhydrous, 99.5%
Sigma-Aldrich
草酸, puriss. p.a., anhydrous, ≥99.0% (RT)
Sigma-Aldrich
乙腈, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
氯化胆碱, BioUltra, ≥99.0% (AT)
Sigma-Aldrich
二氯甲烷, suitable for HPLC, ≥99.9%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
甲苯, JIS special grade, ≥99.5%
Sigma-Aldrich
氯化胆碱, Vetec, reagent grade, ≥98%
Sigma-Aldrich
乙腈, Preparateur, ≥99.9% (GC), One-time steel-plastic (SP) drum