Merck
CN
  • Automated direct-immersion solid-phase microextraction using crosslinked polymeric ionic liquid sorbent coatings for the determination of water pollutants by gas chromatography.

Automated direct-immersion solid-phase microextraction using crosslinked polymeric ionic liquid sorbent coatings for the determination of water pollutants by gas chromatography.

Analytical and bioanalytical chemistry (2015-05-01)
María Cordero-Vaca, María J Trujillo-Rodríguez, Cheng Zhang, Verónica Pino, Jared L Anderson, Ana M Afonso
摘要

Four different crosslinked polymeric ionic liquid (PIL)-based sorbent coatings were evaluated in an automated direct-immersion solid-phase microextraction method (automated DI-SPME) in combination with gas chromatography (GC). The crosslinked PIL coatings were based on vinyl-alkylimidazolium- (ViCnIm-) or vinylbenzyl-alkylimidazolium- (ViBzCnIm-) IL monomers, and di-(vinylimidazolium)dodecane ((ViIm)2C12-) or di-(vinylbenzylimidazolium)dodecane ((ViBzIm)2C12-) dicationic IL crosslinkers. In addition, a PIL-based hybrid coating containing multi-walled carbon nanotubes (MWCNTs) was also studied. The studied PIL coatings were covalently attached to derivatized nitinol wires and mounted onto the Supelco assembly to ensure automation when acting as SPME coatings. Their behavior was evaluated in the determination of a group of water pollutants, after proper optimization. A comparison was carried out with three common commercial SPME fibers. It was observed that those PILs containing a benzyl group in their structures, either in the IL monomer and crosslinker (PIL-1-1) or only in the crosslinker (PIL-0-1), were the most efficient sorbents for the selected analytes. The validation of the overall automated DI-SPME-GC-flame ionization detector (FID) method gave limits of detection down to 135 μg · L(-1) for p-cresol when using the PIL-1-1 and down to 270 μg · L(-1) when using the PIL-0-1; despite their coating thickness: ~2 and ~5 μm, respectively. Average relative recoveries with waters were of 85 ± 14 % and 87 ± 15 % for PIL-1-1 and PIL-0-1, respectively. Precision values as relative standard deviation were always lower than 4.9 and 7.6 % (spiked level between 10 and 750 μg · L(-1), as intra-day precision). Graphical Abstract Automated DI-SPME-GC-FID using crosslinked-PILs sorbent coatings for the determination of waterpollutants.

材料
货号
品牌
产品描述

Sigma-Aldrich
乙腈, anhydrous, 99.8%
Sigma-Aldrich
2-丙醇, for molecular biology, BioReagent, ≥99.5%
Sigma-Aldrich
2-丙醇, anhydrous, 99.5%
Sigma-Aldrich
乙酸乙酯, anhydrous, 99.8%
Sigma-Aldrich
咪唑, ACS reagent, ≥99% (titration)
Sigma-Aldrich
氢氧化钠 溶液, BioUltra, for molecular biology, 10 M in H2O
Sigma-Aldrich
氢氧化钠 溶液, 1.0 N, BioReagent, suitable for cell culture
Sigma-Aldrich
咪唑, ReagentPlus®, 99%
Sigma-Aldrich
环己烷, anhydrous, 99.5%
Sigma-Aldrich
苯酚, puriss. p.a., ACS reagent, reag. Ph. Eur., 99.0-100.5%
Sigma-Aldrich
苯酚 溶液, Equilibrated with 10 mM Tris HCl, pH 8.0, 1 mM EDTA, BioReagent, for molecular biology
Sigma-Aldrich
咪唑, for molecular biology, ≥99% (titration)
Sigma-Aldrich
异丙醇, ≥99.7%, FCC, FG
Sigma-Aldrich
咪唑, puriss. p.a., ≥99.5% (GC)
Sigma-Aldrich
过氧化氢 溶液, 34.5-36.5%
Sigma-Aldrich
2-丙醇, electronic grade, 99.999% trace metals basis
Supelco
双酚 A, ≥99%
Sigma-Aldrich
液状苯酚, ≥89.0%
Sigma-Aldrich
2-丙醇, BioUltra, for molecular biology, ≥99.5% (GC)
Sigma-Aldrich
苯酚, for molecular biology
Sigma-Aldrich
咪唑水溶液, BioUltra, 1 M in H2O
Sigma-Aldrich
4-乙烯基苄氯, 90%
Sigma-Aldrich
苯酚 溶液, Saturated with 0.1 M citrate buffer, pH 4.3 ± 0.2, BioReagent, for molecular biology
Sigma-Aldrich
1-溴丁烷, ReagentPlus®, 99%
Sigma-Aldrich
苯酚, ≥99%
Sigma-Aldrich
乙烯基三甲氧基硅烷, 98%
Sigma-Aldrich
咪唑, BioUltra, ≥99.5% (GC)
Sigma-Aldrich
苯酚, contains hypophosphorous as stabilizer, loose crystals, ACS reagent, ≥99.0%
Sigma-Aldrich
4-叔丁基苯酚, 99%
Sigma-Aldrich
芴, 98%