跳转至内容
Merck
CN

SeQuant® HILIC HPLC Columns

Section Overview

Complete Range for Separations of All Polar Hydrophilic Compounds

SeQuant® HILIC (hydrophilic interaction liquid chromatography) HPLC columns constitute a range of high-performance tools for separating polar hydrophilic compounds. All columns carry densely bonded, truly zwitterionic functional groups with a charge balance of 1:1. Separation is achieved by hydrophilic partitioning combined with weak ionic interactions for maximum selectivity, high loadability and easy optimization of methods.

Features and Benefits

  • High-performance HPLC and LC-MS separations of polar hydrophilic compounds
  • Zwitterionic stationary phase ensures reproducible retention
  • Two complementary phase chemistries
  • Maximum LC-MS compatibility with minimized column bleed
  • Excellent reproducibility and robustness
  • Available in a variety of lengths, particle sizes, and pore dimensions

Choose Your SeQuant® HILIC Selectivity

SeQuant® ColumnFunctional GroupFeaturesBase ParticleParticle SizePore SizeColumn Types
SeQuant® ZIC®-HILIC

I-⊕-⊖

Sulfobetaine

High-performance selectivity and robustnesssilica3.5 µm, 5 µm100 Å, 200 Åanalytical, capillary, semi-prep, guards
SeQuant® ZIC®-cHILIC

I-⊖-⊕

Phosphory-lcholine

Complementary selectivity with favorable LC-MS performancesilica3 µm100 Åanalytical, capillary, guards
SeQuant® ZIC®-pHILIC

I-⊕-⊖

Sulfobetaine

High pH-stability and low noise with ion detectorspolymer5 µm analytical, guards

SeQuant® ZIC®-HILIC

Chemical structure of Sulfobetaine (SB) featuring a silver sphere representing a hydrophobic group, a long carbon chain, and a positively charged nitrogen atom connected to a sulfonate group (SO3). The structure includes various methyl (CH3) groups attached to the carbon chain.

The ZIC®-HILIC Column is designed to retain and separate all types of polar and hydrophilic compounds and for robust chromatography with high selectivity and reproducibility. The silica-based ZIC®-HILIC sorbent has a bonded stationary phase consisting of a highly polar, permanent zwitterion. Separation selectivity is favored by the 1:1 zwitterion charge balance, which makes the ZIC®-HILIC Column overall neutral, with weak, but important, ionic interactions. Tuning of the selectivity on the ZIC®-HILIC Column during method development is facilitated by the pH-inpendent permanent zwitterion, ensuring that only the analytes (and not the column) is affected during eluent optimization.

SeQuant® ZIC®-cHILIC

Chemical structure of Phosphorylcholine (PC) featuring a silver sphere representing a hydrophobic group, a carbon chain connected to a phosphate group (PO4) that includes negatively charged oxygen atoms, and a positively charged nitrogen atom linked to a methyl (CH3) group. The structure illustrates the functional components of phosphorylcholine.

SeQuant® ZIC®-cHILIC is designed for excellent HPLC and LC-MS of polar hydrophilic compounds. This new zwitterionic stationary phase with phosphorylcholine functional group provides you with complementary selectivity for easier method development for substances that have been difficult to separate by previous types of HPLC columns operated in reversed-phase or HILIC mode.

Comparison of chromatograms from SeQuant® ZIC™-HILIC analysis. The left graph shows the retention time of various compounds, with a peak labeled 'DTMA' at around 4 minutes. The right graph presents a similar analysis with a different sample, also featuring a 'DTMA' peak. An inset illustrates the chemical structure of DTMA, highlighting its molecular components.

Isocratic separations of the positively charged benzyltrimethylamine (BTMA, peaks indicated with arrows) and the neutral toluene (void marker), uracil and cytosine on ZIC®-cHILIC (left) and ZIC®-HILIC (right) illustrating differences and similarities in selectivity caused by the different charge orientation of the zwitterionic functional groups (see illustrations). Column dimensions were 100 x 4.6 mM, particles size 3 or 3.5 µm, and pore size 100 Å. Eluent was 80 : 20 acetonitrile/ 25 mM aqueous ammonium acetate pH 6.8 pumped at 0.5 mL/min at 23 °C. Detection by UV absorption at 254 nm.

SeQuant® ZIC®-pHILIC

The ZIC®-pHILIC stationary phase has the same highly polar, bonded, permanent zwitterion, functional group as the silica based ZIC®-HILIC Column. The user can therefore expect the same selectivity, however, with a trade-off in flow-rate range, and separation efficiency, common with polymeric materials. The more durable support allows for use in an extended pH range, which can be beneficial for certain applications.

Example of enhanced selectivity at high pH The application example below illustrates how the selectivity of the ZIC®-pHILIC material can be enhanced by performing the separation at elevated pH. The chromatograms show isocratic separations of gentisic acid, protocatechuic acid and isophthalic acid on a ZIC®-pHILIC Column. The pH-increase also results in higher retention and improved peak shape for these analytes.

Side-by-side chromatograms comparing the retention times of compounds at two different pH levels: 6.8 on the left and 9.6 on the right. Each graph shows a distinct peak pattern, with the pH 6.8 chromatogram displaying a single prominent peak, while the pH 9.6 chromatogram reveals multiple peaks. Inset structures illustrate the chemical compounds analyzed, highlighting their molecular differences at the two pH levels.

SeQuant® ZIC®-HILIC and ZIC®-cHILIC capillary columns

The new SeQuant® ZIC®-HILIC and ZIC®-cHILIC capillary columns are now housed in advanced glass-lined hardware, significantly enhancing their capability to separate a wide array of hydrophilic bio-related molecules, including phosphorylated compounds and peptides. These columns are particularly suited for applications in OMICS fields such as proteomics, metabolomics, and glycomics, where they have demonstrated exceptional performance.

The upgraded hardware, along with an enhanced packing procedure, offers superior reproducibility and stability compared to existing capillary columns.

HILIC columns serve as an ideal complement to reversed-phase liquid chromatography (RPLC) for two-dimensional liquid chromatography (2D-LC). The zwitterionic (ZIC®) HILIC column effectively retains hydrophilic peptides and improves resolution for polar modifications, while the C18 column excels in retaining hydrophobic peptides, facilitating comprehensive analysis of protein digests.

For more information, check out the product flyer for the SeQuant® ZIC®-HILIC and ZIC®-cHILIC Capillary Columns. Additionally, you can explore our white paper on LC-MS/MS characterization of trypsin-cleaved proteins using capillary columns.

Related Products

Ordering Information

 

Length (mm)

ID (mm)

ZIC®-HILIC 200A, 5 µm

ZIC®-HILIC 100A, 3.5 µm

ZIC®-HILIC 200A, 3.5 µm

ZIC®-cHILIC 100A, 3µm

ZIC®-pHILIC, 5µm

SeQuant® HPLC Columns

HPLC Column

50

2.1

1.50450

1.50440

1.50445

1.50656

1.50459

HPLC Column

50

4.6

1.50451

 

1.50446

1.50659

1.50463

HPLC Column

50

21.2

1.50496

    

HPLC Column

100

2.1

1.50452

1.50441

1.50447

1.50657

1.50462

HPLC Column

100

4.6

1.50453

  

1.50660

1.50464

HPLC Column

150

2.1

1.50454

1.50442

1.50448

1.50658

1.50460

HPLC Column

150

4.6

1.50455

1.50444

1.50449

1.50661

1.50461

HPLC Column

150

10

1.50493

    

HPLC Column

150

21.2

1.50497

    

HPLC Column

250

2.1

1.50457

1.50443

   

HPLC Column

250

4.6

1.50458

  

1.50662

 

HPLC Column

250

10

1.50494

    
        

SeQuant® Guard Column & Kit

Guard column

20

2.1

1.50435

1.50439

 

1.50664

1.50437

Guard Kit

20

2.1

    

1.50438

SeQuant® Capillary Columns

Capillary Column

150

0.075

 

1.50465

 

 

 

 

 

Capillary Column

100

0.1

 

 

 

1.50466

 

 

 

Capillary Column

50

0.3

 

 

 

150473-U

 

 

 

150664-U

 

 

Capillary Column

150

0.3

 

150481-U

 

 

150671-U

 

 

150479-U

 

 

150669-U

 

 

Capillary Column

50

1.0

 

 

 

150476-U

 

 

150668-U

 

 

Capillary Column

150

1.0

 

150482-U

 

 

150487-U

 

 

150480-U

 

 

150670-U

 

 

登录以继续。

如要继续阅读,请登录或创建帐户。

暂无帐户?