Merck
CN
  • Embedment of Ag(I)-organic frameworks into silica gels for microextraction of polybrominated diphenyl ethers in soils.

Embedment of Ag(I)-organic frameworks into silica gels for microextraction of polybrominated diphenyl ethers in soils.

Journal of chromatography. A (2015-01-27)
Chao-Yan Zhang, Zeng-Guang Yan, You-Ya Zhou, Lin Wang, Ya-Bo Xie, Li-Ping Bai, Hui-Yan Zhou, Fa-Sheng Li
摘要

Three Ag(I)-organic frameworks, [Ag5(pydc)2(CN)]n, {[Ag4(pydc)2]CH3CN}n, and [Ag(4,4'-bpy)NO3]n, were synthesized and embedded into silica gels to form metal-organic-framework (MOF)-embedded gels for the microextraction of polybrominated diphenyl ethers (PBDEs) in soils. Despite the great differences in the structures of the organic ligands, all three Ag(I)-organic frameworks were found to effectively accumulate and concentrate PBDEs from sample solutions prepared with contaminated soil and purified water, indicating the important roles of Ag centers in PBDE extraction. Under the optimal experimental conditions (MOF mass, water volume, temperature, extraction time, and back-extraction time) for PBDE extraction from sample solutions, the detection limits of seven PBDEs (BDE-28, 47, 99, 100, 153, 154, and 183) ranged from 0.01 to 2.6ngg(-1) for [Ag5(pydc)2(CN)]n, 0.20-0.64ngg(-1) for {[Ag4(pydc)2]CH3CN}n, and 0.60-3.08ngg(-1) for [Ag(4,4'-bpy)NO3]n. The reproducibilities of the three methods were all satisfactory with relative standard deviations (RSDs) in the range of 2.2-9.6%, 5.3-10.4%, and 6.9-9.4% for [Ag5(pydc)2(CN)]n, {[Ag4(pydc)2]CH3CN}n, and [Ag(4,4'-bpy)NO3]n, respectively. The use of Ag(I)-organic frameworks for the microextraction of PBDEs was validated using both certified reference soils and field-contaminated soils, and the proposed methods are recommended as rapid and environmentally friendly alternatives for the extraction and determination of PBDEs in soils.

材料
货号
品牌
产品描述

Sigma-Aldrich
三氟乙酸, ReagentPlus®, 99%
Sigma-Aldrich
三氟乙酸, suitable for HPLC, ≥99.0%
Sigma-Aldrich
甲苯, anhydrous, 99.8%
Sigma-Aldrich
甲苯, ACS reagent, ≥99.5%
Sigma-Aldrich
原硅酸四乙酯, reagent grade, 98%
Sigma-Aldrich
甲苯, suitable for HPLC, 99.9%
Sigma-Aldrich
甲苯, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%
Sigma-Aldrich
三氟乙酸, puriss. p.a., suitable for HPLC, ≥99.0% (GC)
Sigma-Aldrich
原硅酸四乙酯, ≥99.0% (GC)
Sigma-Aldrich
2,2,4-三甲基戊烷, ACS reagent, ≥99.0%
Sigma-Aldrich
三氟乙酸, ≥99%, for protein sequencing
Sigma-Aldrich
2,2,4-三甲基戊烷, suitable for HPLC, ≥99%
Supelco
甲苯, analytical standard
Sigma-Aldrich
2,2,4-三甲基戊烷, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.5%
Supelco
甲苯, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
2,2,4-三甲基戊烷, anhydrous, 99.8%
Supelco
SPME 纤维组件聚二甲基硅氧烷 (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 24 ga
Sigma-Aldrich
原硅酸四乙酯, 99.999% trace metals basis
Sigma-Aldrich
4,4′-联吡啶, 98%
Supelco
SPME 纤维组件聚二甲基硅氧烷 (PDMS), df 100 μm(PDMS, needle size 24 ga, for use with manual holder
Supelco
三氟乙酸, analytical standard
Supelco
SPME 纤维组件聚二甲基硅氧烷 (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 23 ga
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with manual holder
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 23 ga, PDMS/DVB StableFlex, for use with autosampler
Sigma-Aldrich
甲苯, Laboratory Reagent, ≥99.3%
Supelco
残留溶剂-甲苯, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
聚丙烯酸酯 (PA) 固相微萃取萃取头, df 85 μm(PA, for use with autosampler, needle size 24 ga
Sigma-Aldrich
聚二甲基硅氧烷, viscosity 1.0 cSt (25 °C)
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), df 65 μm(PDMS/DVB, for use with autosampler, needle size 23 ga
Sigma-Aldrich
2,2,4-三甲基戊烷, ReagentPlus®, ≥99%