Merck
CN
  • Development and validation of a high-performance liquid chromatography-fluorescence detection method for the accurate quantification of colistin in human plasma.

Development and validation of a high-performance liquid chromatography-fluorescence detection method for the accurate quantification of colistin in human plasma.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2015-01-16)
Divyabharathi Chepyala, I-Lin Tsai, Hsin-Yun Sun, Shu-Wen Lin, Ching-Hua Kuo
摘要

Recently, colistin has become one of the most important drugs for treating infections caused by multidrug-resistant Gram-negative bacteria. Therapeutic drug monitoring is recommended to ensure the safety and efficacy of colistin and to improve clinical outcomes. This study developed an accurate and sensitive high-performance liquid chromatography-fluorescence detection (HPLC-FLD) method for the quantification of colistin in human plasma. The sample preparation included protein precipitation using trichloroacetic acid (TCA) and methanol, followed by in-solid phase extraction (In-SPE) derivatization with 9-fluorenylmethyl chloroformate (FMOC-Cl). A Poroshell 120 EC-C18 2.1×100mm (2.7μm) column was used in the HPLC method with a mobile phase composed of acetonitrile (ACN), tetrahydrofuran (THF), and deionized (DI) water (82%, 2%, 16% (v/v), respectively). Polymyxin B1 was used as the internal standard. The total analysis time was 22min under optimal separation conditions. The HPLC-FLD method was validated over a therapeutic range of 0.3-6.0μgmL(-1). The intra-day and inter-day precisions for colistin A and colistin B were below 9.9% and 4.5% relative standard deviations, respectively. The accuracy test results were between 100.2 and 118.4%. The extraction recoveries were between 81.6 and 94.1%. The method was linear over the test range, with a 0.9991 coefficient of determination. The limit of detection was 0.1μgmL(-1). The validated HPLC-FLD method was successfully applied to quantify the colistin concentrations in 2 patient samples for therapeutic drug monitoring.

材料
货号
品牌
产品描述

Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
四氢呋喃, anhydrous, ≥99.9%, inhibitor-free
Sigma-Aldrich
乙腈, anhydrous, 99.8%
Sigma-Aldrich
四氢呋喃, inhibitor-free, suitable for HPLC, ≥99.9%
Sigma-Aldrich
盐酸, ACS reagent, 37%
Sigma-Aldrich
四氢呋喃, anhydrous, contains 250 ppm BHT as inhibitor, ≥99.9%
Sigma-Aldrich
氢氧化钠, ACS reagent, ≥97.0%, pellets
Sigma-Aldrich
碳酸氢钠, powder, BioReagent, for molecular biology, suitable for cell culture, suitable for insect cell culture
Sigma-Aldrich
氢氧化钠, reagent grade, ≥98%, pellets (anhydrous)
Sigma-Aldrich
碳酸氢钠, ACS reagent, ≥99.7%
Sigma-Aldrich
三氯乙酸, ACS reagent, ≥99.0%
Sigma-Aldrich
四氢呋喃, contains 250 ppm BHT as inhibitor, ACS reagent, ≥99.0%
Sigma-Aldrich
氢氧化钠 溶液, 50% in H2O
Sigma-Aldrich
氢氧化钠 溶液, BioUltra, for molecular biology, 10 M in H2O
Sigma-Aldrich
乙腈, ACS reagent, ≥99.5%
Sigma-Aldrich
氢氧化钠 溶液, 1.0 N, BioReagent, suitable for cell culture
Sigma-Aldrich
硼酸, ACS reagent, ≥99.5%
Sigma-Aldrich
盐酸 溶液, 1.0 N, BioReagent, suitable for cell culture
Sigma-Aldrich
盐酸, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., fuming, ≥37%, APHA: ≤10
Sigma-Aldrich
乙腈, for HPLC, for UV, ≥99.9% (GC)
Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
三氯乙酸 溶液, 6.1 N
Sigma-Aldrich
盐酸, 36.5-38.0%, BioReagent, for molecular biology
Sigma-Aldrich
硼酸, BioReagent, for molecular biology, suitable for cell culture, suitable for plant cell culture, ≥99.5%
Supelco
氯甲酸-9-芴基甲酯, for HPLC derivatization, LiChropur, ≥99.0% (HPLC)
Sigma-Aldrich
氢氧化钠, BioXtra, ≥98% (acidimetric), pellets (anhydrous)
Sigma-Aldrich
碳酸氢钠, ReagentPlus®, ≥99.5%, powder
Sigma-Aldrich
氢氧化钠, puriss., meets analytical specification of Ph. Eur., BP, NF, E524, 98-100.5%, pellets
Sigma-Aldrich
氯甲酸-9-芴基甲酯, 97%
Sigma-Aldrich
氢氧化钠, reagent grade, 97%, powder